- Ideal for line monitoring
- Value priced
- Low power consumption
- Input signal can be used to power meters
- 3 1/2 digit readout, full scale 1999 display
- 1/2" high digits on a high contrast LCD
- Auto-polarity (-) displayed
- User selectable decimal points
- Choice of ±200mV, ±2V, 20V, ±200V, 5 , 50 AAC, Thermocouple, RTD or Frequency
- Choice of 10. 15, 20, , 32 VDC or 115VAC and 240VAC power options
|
|
|
| |
| |
|
|
|
| |
|
|
The Jewell BL Digital panel meter gives you all the
functionality you need with none of the extras you don’t
need. That means simplicity, easy readability, small
footprint, and a low cost.
The MODUTEC BL is easy-to-read and provides a variety of indicators
all in a compact unit. Ease of assembly is one of the BL’s most valuable benefits.
|
|
|
| |
| |
|
|
| |
|
| |
|
| Indicator: |
| Display: |
3 1/2 digits, 7 segments Non-Backlit LCD (1999) |
| Digit height: |
0.5” high digits |
| Polarity: |
Automatic (-) displayed |
| Decimal Point: |
Three positions, external selection |
| Overload: |
Three lower digits blank for readings greater than 1999 counts |
| Low Battery: |
“Low Bat” annunciator for <7.2V (9V power only) |
| Backlighting Options |
| |
• Positive Green Black on Green Background |
| |
• Negative Green Green on Black Background |
| |
• Positive Red Black on Red Background |
| |
• Negative Red Red on Black Background |
| |
• Non-Backlit LCD Black on Grey Background |
| Inputs: |
| 200mVDC & 2VDC |
±(.1% +1 count) typical
±(.2% +1 count) max. |
| 20VDC & 200VDC |
±(.1% +1 count) typical
±(.2% +1 count) max |
| DC Current |
±(.1% +1 count) typical
±(.2% +1 count) max. |
| Universal Selectable Process |
±(.5% +2 counts) |
| AC Voltage |
±(.5% + 1 count) |
| 5A AC Current |
±(.5% +1 count) |
| 50A AC Current |
±(.5% +5 counts) |
| Frequency Inputs |
±.2Hz (40 to 70Hz)
±.5Hz (above 70Hz)
±1Hz |
| Type J thermocouple |
±(.1% +1 count) accuracy
±1.3°C (2.8°F)
conformity error |
| Type K thermocouple |
±(.1% +1 count) accuracy
±1.2°C (2.5°F) |
| Type T thermocouple |
±(.1% +1 count) accuracy
±1.5°C (3.5°F)
conformity error |
RDT
-200°F to +600° F |
±(.2% + 1 count) max |
RDT
-100.0°F to +199.9°F |
±(.2% + 1 count) max |
| Performance |
|
| Conversion Rate: |
2.5 per second |
| Normal Mode Voltage Range: |
≥40db 50Hz-60Hz |
| Common Mode Rejection: |
≥100db 50Hz-60Hz(except isolated DC powered which is ≥80db 50Hz-60hz) |
| Zero Adjust: |
Automatic |
| Temp. Coef: |
200 PPM/°C typical (except thermocouple inputs which are .1°/degree) |
| Power Options: |
| 115V +10%, -15% |
50Hz to 400Hz at 2VA |
| 230V +10%, -15% |
50Hz to 400Hz at 2VA |
| 10 to 15VDC or 20 to 32VDC |
150mA (including backlighting) |
| Compliance |
| FCC: |
Complies with the class B Limits of FCC rules and regulations part 15,sub-part J for conducted and
radiated emissions. |
| Environment |
| Operating Temperature: |
0°C to +50°C |
| Storage: |
-20°C to 70°C |
|
|
| |
| |
|
|
|
|
| |
| |
General Specifcations |
|
|
|
|
|
 |
| |
Related urls: |
|
|
| |
- BL Series, Non-Isolated Power,
Big Little Digital Panel Meters
- BL Series, Isolated Power,
Big Little Digital Panel Meters
- BL170 Series, Flat Paks
Digital Panel Meters
- 1000 Series, Digital Panel Meters
- 1800 Series, Big Digit, Digital Panel Meters
- 2000 Series, Digital Panel Meters
- DW Series, Digital Panel Meters
- PM20 LED Series, Digital Panel Meters
|
| |
|
|
|
|
|
|
|