Characteristics :

  •  4 digit readout, full scale 1999 display
  • 1/2" high digits on a high contrast LCD
  • Auto-polarity (-) displayed
  • Splash and hose proof meeting NEMA 4, NEMA 12, and IPC 55 standards
  • Resistant to damage with a high impact polycarbonate case
  • 110 or 220 VAC,
    9-36 VDC or 24 VAC
    Accuracy: ±(0.05% fs + 2 digits)
  • Scalable in engineering units
  • Custom labels for special readouts
  • User Selectable functions, decimal point, offset, span, process voltage or current, DC voltage
  • Red or green backlit display
 
 
  Product Description:  
space
green_line
 

 

Jewell Series 2000 is the ideal industrial application panel meter. This 1/81 DIN meter is splash and hose proof, with a wide temperature range. The polycarbonate case makes it resistant to knocks. With all of these rugged features, the Series 2000 remains a slim meter, easy to fit in the design

 
 
  Specifications :  
 
green_line
 
space
Display
Display: 3 1/2 digits, 7 segments Backlit LCD (1999)
Digit Height : 0.5" (12.7 mm)
Polarity: Automatic (-) displayed
Decimal Point: Three positions, external selection

Overload:

Three lower digits blank for readings
Backlighting Options
  • Positive Green Black on Green Background
  • Negative Green Green on Black Background
  • Positive Red Black on Red Background
  • Negative Red Red on Black Background
  • Non-Backlit LCD Black on Grey Background
Performance  
Accuracy: ± (0.05% FS +1 counts)
Conversion Rate: 2.5 per second
Normal Mode Rejection: ≥ 40 db 50Hz-60Hz
Common Mode Rejection: ≥ 100db 50 Hz-60 Hz1
Zero Adjust: Automatic
Warmup : 10 Minutes Typical
Temp. Coef: ±200 PPM/°C typical2
Inputs:
200mVDC & 2VDC ±(.1% +1 count) typical
±(.2% +1 count) max.
20VDC & 200VDC ±(.1% +1 count) typical
±(.2% +1 count) max
DC Current ±(.1% +1 count) typical
±(.2% +1 count) max.
Universal Selectable Process ±(.1% +2 counts)
AC Voltage ±(.5% + 1 count)
5A AC Current ±(.5% +1 count)
50A AC Current ±(.5% +5 counts)
Frequency Inputs ±.2Hz (40 to 70Hz)
±.5Hz (above 70Hz)
±1Hz
Type J thermocouple ±(.1% +1 count) accuracy
±1.3°C (2.8°F)
conformity error
Type K thermocouple ±(.1% +1 count) accuracy
±1.2°C (2.5°F)
Type T thermocouple ±(.1% +1 count) accuracy
±1.5°C (3.5°F)
conformity error
RDT
-200°F to +600° F
±(.2% + 1 count) max
RDT
-100.0°F to +199.9°F
±(.2% + 1 count) max
Power Options:
115V +10%,-15%
230V +10%-15%
10 to 28VDC
10 to 15VDC or
20 to 32VDC
50Hz to 400Hz at 2VA
50Hz to 400Hz at 2VA
150 mA (including backlighting)
150mA (including backlighting)
General Specifications
Operating Temperature: -4°F to 140°F (-20°C to + 60°C)
  -22°F to 158°F (-30°C to + 70°C)
Weight: 2 oz.
 
 