Spacer Home Contact_us ob Opportunities ISO_Registration Privacy_Statement
 
Caption_Header
Jewell Instruments/Modutec
SWM Series, Surface or Window Mount
Analog Panel Meters
 
previous URL Next URL
< Links >
 
 
green_line
 
 
Jewell S Series, Analog Panel Meters

Characteristics :

  • Available in: 1 1/2", 2 1/2", 3 1/2 and 4 1/2"
  • AC rectified 3% accuracy
  • AC iron vane 2% accuracy
  • DC moving coil 2% accuracy
  • Available with rugged, high-torque movements for applications with high vibration
  • Self-shielding
  • Fully insulated Barrel
  • Surface mount
 
 
  Product Description:  
space
green_line
 

 

The MODUTEC SWM Series incorporates taut-band/moving-coil movement in a small, fully insulated barrel, making the most of behind-panel space. The handsome styling, result in unparalleled flexibility both for the engineer and designer.

 
 
  Specifications :  
 
green_line
 
space
Display
Scaling: Flat Arc - Customized to any scaling desired, from linear to specialized Cos Ø, square root distributions, with color applications for visual emphasis and to any desired engineering units.
Specific accuracies
Basic Accuracy: ±2.0% of full scale basic accuracy class.
Rectifier Type Meters: ±3% of full scale basic accuracy class.
Expanded Scale Voltmeters: 0.5% of full scale
Frequency Meters: ± .15Hz @45-55Hz and 55-65Hz, ±0.093Hz @ 58-62Hz, ±1.5Hz @350-450Hz
Zero Suppressed Meters: Errors at 20% suppression = ±3%
of end-scale
Higher Accuracy: 1% of Full scale or better
 
Position of use: Vertical (scale) standard
or to specified angle or position
Full scale deflection angle: 100 °
Movement: Taut Band
The absence of friction resulting from this permits greater sensitivities and provides more rugged meters.Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots.
Pivot and Jewel
In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for high vibration environments because of the mechanism’s inherent stability and strength. Accuracy and repeatability are almost equal to the taut-band’s, and good performance from the pivot and jewel construction is the reason for its long popularity.
Case: ABS plastic, Black
Cover: Polycarbonate cover and window.
Overload rating: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained:
20% for six hours.
Burden Data: AC Ammeter 5 amps @ 60 Hz, 0.5VA, Max. .5 Power factor lagging, AC voltmeter - unity power factor.
Response time: 3 seconds (Max.) - Microammeters
2 seconds (Max.) - All other DC ratings
2.5 seconds (Max.) - All AC ratings
Maximum 40% overshoot
General:
Operating Temp.: 0 to 40°C (32 to 104°F)
Storage Temp: -10 to 50°C (14 to 50°F)
Extreme temperature range:

-20°C to 65°C (-4 to 149°F)
Tropicalized or IP54 sealed units available

Relative Humidity: 95% (non condensing)
 
 
  Downloads:  
space
green_line
 
  pdf_pic Downloads: General Specifcations  
base

 

 

 

 
 
Scroll down
 
scroll
 
  scroll up  
 
web