| General Specifications |
| Accuracy ( 23±3°C ) |
Accuracy : 1% RO / 23 + 3 °C |
| Input of stator : |
|
| Effective range : |
60 / 120 / 240 + 40% order on request |
| Angle of conversion : |
Standard 330° + 30°
|
| Burden : |
< 1VA of maximum range |
| Frequency : |
55 - 65 Hz |
| Dielectric strength |
4KV AC rms 1 minute between input / output / power / case IEC688
* Impulse Test : ANSI C37.90 / 1989, IEEE 587 / 1983, IEC 255-3, 6KV ( 1.2 * 50us), 3KA (8 * 20us)... current only
* Surge Test (ring wave) : IEEE 587 / 1983 (3KV - 0.5 us / 100 KHz), IEC255-3 (2.5KV - 0.25ms / 1MHz) |
| Output drive capability |
>10mA for voltage mode,
>
10V for current mode
Maximum
10kΩ for resistance mode
|
| Response time & ripple |
< 600 ms from 0 to 99% RO at operating
Ripple < 0.5% P-P RO |
| Output impedance |
> 30 Mega ohm |
| Stability |
| Temperature stability < 0.1% per degree C, from 99% RO at operating |
| Long term stability < 1% RO per year |
| Storage condition |
Temperature range -25 to 70°C, RH 20 to 95% non condensed |
| Operating condition |
Temperature range -5 to 60 °C, RH 20 to 99% non condensed |
| Power dissipation: |
< 3.5VA |