General Specifications |
Accuracy ( 23±3°C ) |
Accuracy : 1% RO / 23 + 3 °C |
Input of stator : |
|
Effective range : |
60 / 120 / 240 + 40% order on request |
Angle of conversion : |
Standard 330° + 30° |
Burden : |
< 1VA of maximum range |
Frequency : |
55 – 65 Hz |
Dielectric strength |
4KV AC rms 1 minute between input / output / power / case IEC688* Impulse Test : ANSI C37.90 / 1989, IEEE 587 / 1983, IEC 255-3, 6KV ( 1.2 * 50us), 3KA (8 * 20us)… current only* Surge Test (ring wave) : IEEE 587 / 1983 (3KV – 0.5 us / 100 KHz), IEC255-3 (2.5KV – 0.25ms / 1MHz) |
Output drive capability |
>10mA for voltage mode,>
10V for current modeMaximum
10kΩ for resistance mode |
Response time & ripple |
< 600 ms from 0 to 99% RO at operatingRipple < 0.5% P-P RO |
Output impedance |
> 30 Mega ohm |
Stability |
Temperature stability < 0.1% per degree C, from 99% RO at operating |
Long term stability < 1% RO per year |
Storage condition |
Temperature range -25 to 70°C, RH 20 to 95% non condensed |
Operating condition |
Temperature range -5 to 60 °C, RH 20 to 99% non condensed |
Power dissipation: |
< 3.5VA |