| |
|
|
|
|
| |
|
|
| |
|
|
| |
| |
|
|
|
|
| |
|

|
| Input |
Option |
Option |
Option |
Option |
Output |
| Voltage |
45~86 |
85~150 |
180~300 |
300~500 |
0-1 mA |
0-20 mA |
4-20 mA |
| Current |
0 - 1.2 A |
0 - 6 A |
4~12
~20 mA |
0~10 mA |
0~1 V |
| Hz |
48 - 52 Hz |
58 - 62 Hz |
0~5 V |
0~10 V |
2~10 V |
| Aux. Pwr. |
120V |
240V |
AC 415V / Internal powered * |
1~5 V |
1~3~5 V |
|
| *DC powered- on request |
|
|
| |
RPW - Watt Transducers
RPK- Var Transducers |
| Model |
Application |
Standard Analog Cal. |
| Watts |
Vars |
Elements |
1A |
5A |
|
| |
|
|
|
| RPW101 |
RPK101 |
1E |
1Ø 2W |
100
200
400 |
500
1K
1.5K |
120V
240V
415V |
| RPW200 |
RPK200 |
1.5E |
3Ø 3W |
100
200
400 |
500
1K
1.5K |
120V
240V
415V |
| RPW201 |
RPK201 |
2E |
3Ø 3W* |
200
400
800 |
1K
2K
4K |
120V
240V
415V |
| RPW300 |
RPK300 |
2.5E |
3Ø 4W |
100
200
400 |
500
1K
1.5K |
120V
240V
415V |
| RPW301 |
RPK301 |
3E |
3Ø 4W* |
200
300
600
1.2K |
1K
1.5K
3K
6K |
69.3V
120V
240V
415V |
| |
| Notes |
- Note :
Voltage input :
Phase voltage for 3 phase 4 wire (Vp)
Line to line voltage for 3 phase 3 wire (VL)
- Note :
1. uni. = uni-direction = 0 to +span bi = bi-direction = -span to 0 to +span
Example : 4-20mA = 0 to +1000W 4-12-20mA = -1000W to 0 to +1000W
2. For uni-directional transducers, watts for forward power and vars for lagging power
3. For internal powered type ... zero based outputs and Vn operation range 85%~115%
*Unbalanced
|
|
| |
| |
|
|
| |
|
| |
| General Specifications
|
| Accuracy ( 23±3°C ) |
0.2% RO |
| Maximum output load |
Current related input : 2 x rated continuous, 10 x rated 10 sec, 25 x rated 2 sec, 50 x rated 1 sec
Voltage related input : maximum 2 x rated continuous ( 120V / 240V ), maximum 1.5 x rated continuous ( 415V ) |
| Dielectric strength |
4KV AC rms 1 minute between terminals to case IEC 688
2KV AC rms 1 minute between input / output / power IEC 688 |
| Impulse / SWC |
IEC 255-4, 5KV 1.2x50us, IEC255-22-1, 2.5KV ( 1MHz / 400Hz ) |
| Input burden |
Current 0.3VA typically; voltage 0.2VA typically |
| Response time & ripple |
< 400ms for step change 0-95%, ripple less 0.5% ro peak-peak |
| Frequency |
50± 2Hz, 60 ±2Hz |
| Aux. power effect |
< 0.005% for per voltage change |
| Stability |
| Temperature range ( 20 to 26°C ) long term stability / year |
| Maximum 100ppm/ , less 0.2% drift per year typically |
| Storage condition |
Temperature range -25 to 70°C, RH 20 to 95% non condensed |
| Operating condition |
Temperature range -20 to 65°C, RH 0 to 99% non condensed |
| Magnetic field effect |
< 0.05% change 1M center 100 amper-turn, synchronized with line frequency |
| Enclosure code Case |
IP 50 / terminals IP 30, complies with IEC 529, BS 5490 DIN 40050 |
| Power supply |
AC 120V / 240V 15%, 50 / 60Hz |
| Power dissipation |
< 3.5 VA |
|
| |
| |
|
|
|
|
| |
| |
General Specifications |
|
|
|
|
|
 |
| |
Related urls: |
|
|
| |
- Model RPW / RPK- Watt or Var Transducers Series
- Model RPWK- Watt and Var Transducer Series
- Model RPWH / RPKH- Watt hour and Var hour Transducer Series
- Model RPWWH / RPKKH, Transducers
Watt /
Watt hour and Var / Var hour
- Model RPV / RPVR / RPVS, RPV2, AC Voltage Transducer Series
- Model RPVX / RPVXS / RPVX2,
AC Voltage Transducer Series
- Model RPA / RPAR / RPAS, RPA2, AC Current Transducer Series
- Model RPAX / RPAXS / RPAX2,
AC Voltage Transducer Series
- Model RPPF, Power Factor Transducer Series
- Model RPPL, Phase Angle Transducer Series
- Model RPF, Frequency Transducer Series
|
| |
|
|
|
|
|
|
|