Grant

SQ2040 Wi-Fi, (Squirrel 2040 Wi-Fi)
Portable Data Logger

 
previous URL Next URL
< Links >
 
 
 
SQ2020 WIFI
 
  Characteristics:  
 
 
  • Integral Wi-Fi Ethernet networking
  • High precision (0.05%)
  • Advanced data management, to MMC/SD or PC
  • Flexible communications (USB, Ethernet, RS232)
  • High speed option (100Hz on 4 channels)
  • Various Remote connection options e.g. via Ethernet or dial up modem
  • High precision (0.05%)
  • High speed option (100Hz on 4 channels)
  • User selectable logging rates of up to 100Hz on up to 4 channels
  • Large non-volatile internal memory – data retention is virtually indefinite
  • Sensor power and FET outputs for use with external devices
  • Comprehensive access to information using the 2 line, 20 character LCD and button panel
  • Calculated channels derived from real channels using advanced mathematical functions e.g. log(x); ln(x); sqrt(x)
******* 3 year warranty ******
 
  Key Features:  
 
 
  • Standalone data logger or link to a PC
  • Compact and portable
  • 16 to 32 universal analog plus 8 digital inputs
  • 16 derived/calculated channels
  • 4 alarm outputs
  • Configured via integral interface or via PC
  • 0.05% basic accuracy
  • Up to 1.8 million readings
  • In built Ethernet networking capability
  • USB and RS232 connectivity
  • Analog Inputs Supported
  • Thermistors
  • Thermocouples
  • Pt100/Pt1000 (maximum of eight 3- or 4-wire Pt100/1000 sensors - model 4F16 only)
  • Voltage
  • Current
  • Resistance
 
 
  Product Description:  
 

space

The Squirrel SQ2040 Wi-Fi series combines a high channel, high performance, universal inputs with the simplicity of Wi-Fi networking in a compact and portable instrument.

Using multiple 24-bit analogue to digital convertors, twin processors and removable memory and Wi-Fi networking the SQ2040 Wi-Fi provides great flexibility to handle a wide range of complex and demanding multi-channel applications. The Squirrel SQ2040 Wi-Fi series is ideal for industrial, scientific research and quality assurance applications. The SQ2040 Wi-FI provides standalone data acquisition, advanced networked solutions and data analysis straight out-of-the-box.

 
 
 
Concurrent sampling:
The SQ2040 Wi-Fi series uses multiple analogue to digital converters that enables true concurrent sampling and logging. This allows the user to configure up to 4 channels to log at a rate of 100Hz whilst retaining different sample speeds on other channels. This makes the SQ2040 Wi-Fi series ideal for measuring dynamic parameters that change at different rates such as temperature and pressure.

Multiple configurations stored in the logger:
Up to six logger configurations (channel type, names, logging speeds, triggers etc), together with the current configuration, can be held in the logger’s internal memory. Additional configuration settings can also be loaded from the external MMC/SD memory card. This allows the operator to quickly and easily switch between logger configurations without the need for a PC.

Communications:

Wireless Ethernet, USB and RS232 serial ports are built-in. This allows simple wireless connection to a PC based TCP/IP network, or to a modem for remote data downloading. This flexibility enables global data access and retrieval as well as complete system integration of the SQ2040 Wi-Fi series into complex and critical applications.

Comprehensive software configuration via SquirrelView:
The SquirrelView software (supplied with the SQ2040 Wi-Fi series) allows logger configuration, data download and data export whilst giving the user full control over the SQ2040 Wi-Fi. The optional SquirrelView Plus gives the user access to many advanced data analysis and data archiving/transfer features.
 
 
  General Information:  
 
 
|||||||| Click here for General Specifications
SQ2040 Handheld Data Logger
Analog Input Channels SQ2040 - 2F16
No. of channels 16 true differential or 32 single ended universal analog inputs for voltage, current or resistance
Analog to Digital Converters 2
3 or 4 wire 0 channels
Analog Input Channels SQ2040 - 4F16
No. of channels 16 true differential or 32 single ended universal analog inputs for voltage, current or resistance
Analog to Digital Converters 4
3 or 4 wire 8 channels
Additional Channels
Pulse (2 x fast – 64kHz) & (2 x slow – 100Hz)
Event / digital 8 state inputs or 1 x 8 bit binary
High voltage 2
Internal channels 2 temperature
Standard ranges for temperature channels:
Each channel can be individually set to any of the ranges listed below. Pt100 to IEC751 and JIS1604 and Pt1000 to IEC751.
Y & U: Thermistor -50 to 150°C ( -58 to 302°F )
Pt100/Pt1000* -200 - 850 °C ( -328 to 1562 °F )
*2 wire only on 1F8
Thermocouples
K: Thermocouple -200 to 1372 °C ( -328 to 2501 °F )
T: Thermocouple -200 to 400 °C ( -328 to 752 °F )
J: Thermocouple -200 to 1200 °C ( -328 to 2192 °F )
N: Thermocouple -200 to 1300 °C ( -328 to 2372 °F )
R & S: Thermocouple -50 to 1768 °C ( -58 to 3214 °F )
Voltage Ranges
-0.075 to 0.075V -0.15 to 015V -0.3 to 0.3V -0.6 to 0.6V -0.6 to 1.2V -0.6 to 2.4V -3.0 to 3.0V -6.0 to 6.0V - 6.0 to 12.0V -6.0 to 25.0V 4.0 to 20.0V 4.0 to 40.0V 4.0 to 60.0V
Current range
(External 10Ω shunt) -30.0 to 30.0mA 4 to 20mA
Resistance Ranges
Resistance range 2 wire 0.0 to 1250.0 Ω 0.0 to 5000.0 Ω 0.0 to 20000.0 Ω 0.0 to 300000.0 Ω
Resistance range 3 - 4 wire (2F8 version) 0.0 to 500.0 Ω 0.0 to 4000.0 Ω
Analog inputs: Accuracy & Resolution
A/D Resolution 24 bit
Sampling rate: Up to 10, 20* or 100* readings per second per ADC.
Accuracy: ± (0.05% readings + 0.025% range)
Resolution: Up to 6 significant digits
Common mode rejection: 100dB
Input impedance: > 1M Ω
Linearity: 0.015%
Series mode line rejection: 50/60Hz 100dB
Logging Speeds: 1 sec to 1 day in 1 sec increments 2, 5, 10, 20 or 100Hz (20Hz or 100Hz only on 2 channels)
*with mains rejection off
Outputs
Alarm outputs 4 x open drain FET (18V 0.1A)
Power output for external device Regulated 5 VDC at 50mA or logger supply voltage at 100mA
 
Time and date built-in clock, 3 formats
Calculated channels Up to 16 virtual channels derived from physical input channels
Programming/logger setup SquirrelView or SquirrelView Plus software
Scaling data Displays readings in preferred engineering units
Memory Internal 16Mb (Up to 1,800,000 readings)
Memory external Up to 1Gb - removable MMC/SD (For transferring internal memory and storing setups only)
Internal memory modes Stop when full or overwrite
Calcuated channels built-in clock, 3 formats
Calculated channels Up to 16 virtual channels derived from physical input channels
Resolution Up to 6 significant digits
Programming/logger setup SquirrelView or SquirrelView Plus software
Communications / Setup
Networking Ethernet (on 2F8), USB and RS232 serial ports are built-in. PC based TCP/IP network or wireless connection
Modem Support GSM modem for remote data downloading
PC Setup Yes, SquirrelView compatible
Front Panel Setup This flexibility enables global data access and retrieval as well as complete system integration of the SQ2020 series into complex and critical applications.
Third Party Programming As 20xx driver suite allows
Dsiplay
LCD Display: 2 line x 20 character LCD display Battery state and external power indicator Keypad lock
Navigate to: Arm/disarm/pause/continue Meter any channel or alarm Select from up to 6 x pre-stored setups Status/diagnostics/memory/time and date Download to MMC/SD
Power
Internal Battery 6 x AA Alkaline batteries
External Power 10-18VDC Reverse polarity and over-voltage protected
Power consumption @ 9V: Sleep mode: 600μA Logging: 40-130mA
General
Operating temp -30°C to +65°C
Humidity: 90% at 40°C non-condensing
Dimensions W235 x D175 x H55mm
Weight: Approx 1.2kgs
Enclosure material: ABS plastic
 
 
 
|||||||| Click here for Channel Inputs | Connectivity | Navigation
SQ2020 Channel inputs | Connectivity | Navigation
Features
  • Create complex schedules of logging rates, triggers and alarm outputs
  • Scale and view readings in real time on the integral display or on a PC running Excelä
  • Display readings in preferred engineering units e.g. Hz, Bar, Pascals, Nm etc.
  • Select logging rates up to 100 readings per second on up to 4 channels (2 channels on Squirrel model 2040-2F16) or a combination of different logging rates
  • Derive up to 16 calculated (virtual) channels from real input channels using mathematical functions
  • Concurrently sample channels at different sample speeds, e.g. 100Hz, 20Hz, and 10 Hz etc
pdf_pic 2F16 Logging Speeds | 4F16 Logging Speeds
Bottom View
Connectivity
SQ2040WIFI
General Overview
  1. 16 to 32 universal analogue inputs for recording temperature, current, voltage and resistance
  2. Easy to use, removable connector system
  3. Power output for sensor excitation / external devices
  4. 2 high voltage channels (20, 40 or 60V) for automotive applications
  5. USB, Ethernet and RS232 connectivity for quick and easy PC and remote communication and networking
  6. Range of trigger functions via 8 digital inputs; 4 pulse rate / counter inputs
    • 4 alarm outputs for triggering external devices
  7. Power supply – internal alkaline batteries or external DC power supply
 
Facade
Navigation
Squirrel 2040 Façade
General Overview
  1. To operate the logger simply use the four integral push buttons and display, or use the convenient SquirrelView set-up, download and export software – free with every Squirrel logger
  2. Convenient 2 line x 20 character backlit LCD for easy access to readings and set-up information
  3. Robust, ergonomically designed case with easy access to all user facilities
    • Store up to 1.8 million readings in the Squirrel’s onboard memory
    • Store up to 6 logger configurations. Load from a removable MMC / SD card for speed and convenience, or download data files to the card
 
 
|||||||| Click here for Models
SQ2020
Standard Model
Squirrel 2040-2F16 Wi-Fi

Includes the following;

  • Up to 100 readings per second on 2 channels
  • Two 24-bit A to D converters
  • In built Ethernet connectivity
 
SQ2020
high speed model
Squirrel 2040-4F16 Wi-Fi (high speed model)

Includes the following;

  • Up to 100 readings per second on 4 channels
  • Four 24-bit A to D converters
  • 4 pulse rate / counter inputs (2 at up to 64kHz, 2 at up to 100Hz)
  • In built Ethernet connectivity
 
 
|||||||| Click here for Software Options
SQ2020 Paint Software
Paint View
PaintView Software   pdf_pic PaintView Data Sheet
 
Minimum PC specification

Windows® 2000, XP; Pentium II 266MHz, 60Gb HDD, colour SVGA screen, at least one RS232 or one USB port.

General Overview

PaintView is an easy-to-use software package designed for exclusive use in the paint and finishing industry and is included free with every OQ610 temperarture logger. It enables easy setup of the logger and automatic download of data from the logger into a meaningful measure of paint cure.

For advanced paint cure calculations, it can also provide rapid interpretation of results. PaintView also gives the additional benefits of graphically analysing historical and on-line data, along with advanced reporting.

PaintView can be easily set-up in the minimum amount of time and with the least amount of hassle. With regular usage it can pin-point any uneven temperatures within the stoving process. This will improve the quality of your process, so that fewer faults occur, and helps to avoid costly re-work in the future.

 
SQ2010 SquirrelView Software
General Software - Free with every Data Logger
PaintView Software  

pdf_pic SquirrelView Data Sheet

pdf_pic How to use Data Sheet
Minimum PC specification

Windows® 2000, XP; Pentium II 266MHz, 60Gb HDD, colour SVGA screen, at least one RS232 or one USB port.

General Overview

SquirrelView is a universal software package that is supplied free with every new Grant Squirrel data logger.

Its intuitive, user friendly, spreadsheet style interface allows quick set-up of the logger for any application, speedy download of data and direct export to Excel.

Key features of SquirrelView

  • Export data into Excel or as a CSV file for customisable data analysis
  • Easily view and control the logger status from one single screen
  • Use the simple communication wizard for hassle free working with modems, Ethernet, GSM, etc.
  • Download data by date, time or events, saving time when working via modem or looking for specific data
  • Save settings on the PC for efficient re-use
  • Protect your data and set-up configurations with the security function

For full analysis and reporting facilities SquirrelView Plus is available as an add-on option (a free 30-day trial is included with the SquirrelView software).

 
SQ2010 SquirrelViewPlus Software
with Graphical Analysis
PaintView Software  

pdf_pic SquirrelView Data Sheet

pdf_pic How to use Data Sheet
Minimum PC specification

Windows® 2000, XP; Pentium II 266MHz, 60Gb HDD, colour SVGA screen, at least one RS232 or one USB port.

General Overview

SquirrelView Plus has all the features of SquirrelView with the additional benefits of allowing graphical analysis of historical and on-line data, whilst providing advanced reporting options. SquirrelView Plus allows quick and easily analysis of the Squirrel data in a familiar Explorer navigation-style interface.

Data can be displayed with two different auto scaling Y-axes ? essential for displaying widely varying data from different sensors on one graph. Particular data of interest can be zoomed into whilst an on-screen cursor can pick out exact values. Data can be shown in a statistical summary with set high and low alarm thresholds. The powerful calculation function allows the creation of “virtual” new channels from existing channels e.g. value from channel 1 added to the average of 10 readings from channel 2 etc.

  • Flexible data presentation allows you to quickly display and analyse real time or historical data as a line graph, bar chart or analog gauge
  • Graphical alarm and event identification lets you easily identify occurrences around specific analog or digital events, e.g. a pump switching on
  • Quick Graph function lets you quickly and easily view large data files
  • Wizards for easy set-up of communications and data export
  • Ability to send real time metered data from the Squirrel directly into Excel
  • Downloader for automating data download using MS Scheduler® (Squirrel 2010, 2020 and 2040 only).
  • Fully configurable data views
  • Flexible zoom feature including X and Y axes
  • Customizable report facility: print out graphs, readings, etc.
  • Tolerance curve
  • Calculated channels
  • Product cure calculation
  • Display oven profiles and oven zones
 
 
   
   
 
  Downloads:  
 