Grant Squirrel 2010 ( SQ2010 ) Portable Data Logger / Data Recorder
 
  Characteristics:  
 
 
  • Flexible, easy to use
  • Economical
  • Handheld, full portability
  • USB and RS232 connectivity for quick and easy PC and peripherals communication e.g. Ethernet converter, Wi-Fi wireless converter or GSM modem
  • 4 differential or 8 single ended channels
  • RS232 output for modem and wireless connection
    (via interface units)
  • Power supply—internal alkaline batteries, external DC power or via USB connection to PC
  • Power output for sensor excitation / external devices
 
  Key Features:  
 
 
  • Small truly portable data logger
  • up to 10 readings per second per channel
  • 4 to 8 universal analog inputs (current, voltage, resistance, temperature) plus 8 digital inputs
  • 16 derived / calculated channels
  • Logging rates of up to 100Hz on up to two channels (on the 2F8)
  • 2 alarm outputs and 2 pulse counter inputs (1 at 64 KHz, 1 at 100Hz)
  • Configured via large easy-to-read graphical display
  • 0.1% accuracy
  • Up to 1.8 million readings
  • Supplied with SquirrelView set-up / download software
  • Easy-to-use removable connector system
  • Power output for sensor excitation / external devices
 
 
  Product Description:  
 

space

The Squirrel 2010 is a general purpose, multi-channel data logger with 4 to 8 analog input channels to measure current, voltage, resistance and temperature, plus 8 digital channels to automatically trigger or stop logging and is network ready.

The SQ2010 is a truly portable logger with a large graphical display, ideal for bench use and with a basic accuracy of 0.1% it is able to fulfil routine data logging and more demanding applications that may require up to 10 readings per second per channel.

 
 
  General Information:  
 
 
|||||||| Click here for General Specifications
SQ2100 Handheld Data Logger
 
No. of channels 8 single ended or 4 differential inputs
Chan. expansion No
Voltage Ranges

Differential:

(-6 to 25, -0.6 to 2.4, ±0.3V, -0.15 to 0.15,
-0.075 to 0.075)
Single Ended: (-6 to 12, -6 to 6, -3 to 3, -0.6 to 1.2, -0.6 to 0.6)
Common mode 25V
Current Ranges
Differential 4 to 20mA, ±30mA
(Requires external 10Ω shunt)
Temperature Ranges
Differential and Single Ended -200 to 1200°C, J-type
-200 to 1372°C, K-type
-200 to 1300°C, N-type
-50 to 1768°C, R-type
-50 to 1768°C, S-type
-200 to 400°C, T-type
Pt100/1000, 2-wire -200 to 850°C
Thermistor Ranges -50 to 150°C, U & UU-type
-50 to 150°C, Y-type
-30 to 150, S-type
Internal reference temperature -50 to 150°C
 
Resistance Ranges, all 2 wire 0 to 1250Ω, 0 to 5000Ω
0 to 300000Ω, 0 to 20000Ω
Pulse Count Ranges 0 to 100Hz (1 input)
0 to 64kHz (1 input)
0 to 16000000 Count
Digital State/Event Ranges 8 state inputs or 1 x 8 bit binary
Digital/Alarm Outputs 2 open drain FETs, 18V, 0.1A
Accuracy & Resolution
A/D Resolution 24 bit
Accuracy 0.1% of range + 0.1% of reading
Clock Resolution/Accuracy 1s/10ppm Normal Mode – each input sampled at a maximum rate of 1 reading per second. Double-speed (mains reject off) – one input can be sampled at 10 readings per second and all others are sampled at a maximum rate of 1 reading per second
Data
Data Statistics Yes from within SquirelView Plus PC software
Data Scaling Yes
Calculated Channels Yes, up to 16
No of Intervals 4
Memory Internal 16M (1 to 1.8 million readings)
Stored setups 6
Communications / Setup
Networking Via RS232 to Ethernet adaptor (Netport, part no. SQ20A801)
Modem Support Via RS232 modem (GSM Modem, part no. SQ20A802)
PC Setup Yes, SquirrelView compatible
Front Panel Setup Via 4 integral 4 keys. All essential functionality available via key pad e.g. channel configuration, start / stop logging etc. Other advanced functions e.g. calculated channels and channel descriptions are available via connection to a PC running SquirrelView
Third Party Programming As 20xx driver suite allows
Power
Display 128*64 dot graphical display, 4 button keypad
Internal Battery 2 C cells
Battery Life Up to 5 days with continuous usage whilst sampling all channels once per second
External Power Yes, 8 to 28V dc & USB when plugged in
Sensor Power Output 5V at 50mA, external 8-28V at 100mA (when connected)
General
Operating temp -20 to 65°C
Dimensions W175 x D135 x H55mm
Weight: Approximately 0.7 g
Enclosure material: ABS plastic
 
 
 
|||||||| Click here for Channel Inputs | Connectivity | Navigation
 
|||||||| Click here for Models
SQ2010
Standard Model
SQ2010

Includes the following;

  • Fitted Foam Lined Case
  • SquirrelView Software
  • Getting Started Guide including Certificate of Conformity
  • USB connection cable
  • Full set of Connection Plugs complete with Cable Ties
  • Pack of 4 Precision Resistors for 4-20mA connection
  • Set of C type Batteries
  • Small Electrical Screwdriver
 
SQ2010 KIT
General Software - Free with every Data Logger
SQ2010
  • Fitted Foam Lined Case
  • SquirrelView Software
  • Getting Started Guide including Certificate of Conformity
  • USB connection cable
  • Full set of Connection Plugs complete with Cable Ties
  • Pack of 4 Precision Resistors for 4-20mA connection
  • Set of C type Batteries
  • Small Electrical Screwdriver
  • SquirrelView Plus Software
  • Universal Power Adaptor (110-240 Vac)

 


 
 
|||||||| Click here for Software Options
SQ2010 Paint Software
Paint View
PaintView Software   pdf_pic

PaintView Data Sheet
 
Minimum PC specification

Windows® 2000, XP; Pentium II 266MHz, 60Gb HDD, colour SVGA screen, at least one RS232 or one USB port.

General Overview

PaintView is an easy-to-use software package designed for exclusive use in the paint and finishing industry and is included free with every OQ610 temperature logger. It enables easy setup of the logger and automatic download of data from the logger into a meaningful measure of paint cure.

For advanced paint cure calculations, it can also provide rapid interpretation of results. PaintView also gives the additional benefits of graphically analyzing historical and on-line data, along with advanced reporting.

PaintView can be easily set-up in the minimum amount of time and with the least amount of hassle. With regular usage it can pin-point any uneven temperatures within the stove process. This will improve the quality of your process, so that fewer faults occur, and helps to avoid costly re-work in the future.

 
SQ2010 SquirrelView Software
General Software - Free with every Data Logger
PaintView Software  

pdf_pic

SquirrelView Data Sheet


pdf_pic

How to use Data Sheet
Minimum PC specification

Windows® 2000, XP; Pentium II 266MHz, 60Gb HDD, colour SVGA screen, at least one RS232 or one USB port.

General Overview

SquirrelView is a universal software package that is supplied free with every new Grant Squirrel data logger.

Its intuitive, user friendly, spreadsheet style interface allows quick set-up of the logger for any application, speedy download of data and direct export to Excel.

Key features of SquirrelView

  • Export data into Excel or as a CSV file for customizable data analysis
  • Easily view and control the logger status from one single screen
  • Use the simple communication wizard for hassle free working with modems, Ethernet, GSM, etc.
  • Download data by date, time or events, saving time when working via modem or looking for specific data
  • Save settings on the PC for efficient re-use
  • Protect your data and set-up configurations with the security function

For full analysis and reporting facilities SquirrelView Plus is available as an add-on option (a free 30-day trial is included with the SquirrelView software).

 
SQ2010 SquirrelView Plus Software
with Graphical Analysis
PaintView Software  

pdf_pic

SquirrelView Data Sheet


pdf_pic

How to use Data Sheet
Minimum PC specification

Windows® 2000, XP; Pentium II 266MHz, 60Gb HDD, colour SVGA screen, at least one RS232 or one USB port.

General Overview

SquirrelView Plus has all the features of SquirrelView with the additional benefits of allowing graphical analysis of historical and on-line data, whilst providing advanced reporting options.
SquirrelView Plus allows quick and easily analysis of the Squirrel data in a familiar Explorer navigation-style interface.

Data can be displayed with two different auto scaling Y-axes ? essential for displaying widely varying data from different sensors on one graph. Particular data of interest can be zoomed into whilst an on-screen cursor can pick out exact values. Data can be shown in a statistical summary with set high and low alarm thresholds. The powerful calculation function allows the creation of “virtual” new channels from existing channels e.g. value from channel 1 added to the average of 10 readings from channel 2 etc.

  • Flexible data presentation allows you to quickly display and analyze real time or historical data as a line graph, bar chart or analog gauge
  • Graphical alarm and event identification lets you easily identify occurrences around specific analog or digital events, e.g. a pump switching on
  • Quick Graph function lets you quickly and easily view large data files
  • Wizards for easy set-up of communications and data export
  • Ability to send real time metered data from the Squirrel directly into Excel
  • Downloader for automating data download using MS Scheduler® (Squirrel 2010, 2020 and 2040 only).
  • Fully configurable data views
  • Flexible zoom feature including X and Y axes
  • Customizable report facility: print out graphs, readings, etc.
  • Tolerance curve
  • Calculated channels
  • Product cure calculation
  • Display oven profiles and oven zones


 
 
   
   
 
  Downloads:  
 
  pdf_pic  Downloads: Specifications
Downloads: Manual
 
base
 
 
 
Scroll down
 
scroll
 
  scroll up  
 
web mail