DEIF A/S DPR & DSM Series

Edgewise DIN Analog Panel Meters

space

Deif DPR and DSM edgewise DIN Meters

 Characteristics:
  • Full Line of edgewise meters
  • DPR are available in 48×24, 72×36, 96×48, 144×72 (vertical or horizontal)
  • DSM are available in 72×24, 96×24, 144×36 (vertical or horizontal)
  • Overload of 120% of rated capacity, continuous
  • Accuracy: DC ±1.5% of full scale
  • Tracking: ± 2% DC
  • Overshoot: ©˜5% of scale length
  • IP54 or Tropicalized meters available
  • Wide Range of inputs – to customer’s specifications
Product Description:
space

These high quality meters comply with DIN EN60051 (IEC51) requirements , with a standard accuracy of ±1.5% of full scale or better.

Dief meters are designed for applications that require reliable, rugged instruments with high resolution readings. They are manufactured from self-extinguishing, polycarbonate housing or sheet metal housing . Scales are easily interchangeable for maximum scaling flexibility, along with Gossen’s patent mechanical movements, making these meters ideal for any application.

The optimum scale display area allows for the use of large, easy to read numerals and divisions. Gossen also offers outstanding meter performance, providing exceptional accuracy, tracking and repeatability.

Specifications :
space
space
Meter Types
Edgewise DCA, DCV, ACA, ACV and Hz
Edgewise Relay Meters DCA, DCV, ACA, ACV and Hz
Display
Scaling: Customized to any scaling desired, from linear to specialized Cos Ø, square root distributions, with color applications for visual emphasis and to any desired engineering units.
Specific accuracies
Basic Accuracy: ±1.5% of full scale basic accuracy class.
Rectifier Type Meters: ±2% of full scale basic accuracy class.
Expanded Scale Voltmeters: 0.5% of full scale
Frequency Meters: ± .15Hz @45-55Hz and 55-65Hz, ±0.093Hz @ 58-62Hz, ±1.5Hz @350-450Hz
Zero Suppressed Meters: Errors at 20% suppression = ±2% of end-scale
Higher Accuracy: 1% or better of Full scale or better
Position of use: Vertical (position) standardor to specified angle and/or position
Full scale deflection: 90 °
Movements: Taut Band
The absence of friction resulting from this permits greater sensitivities and provides more rugged meters.Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots.
Pivot and Jewel
In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for high vibration environments because of the mechanism’s inherent stability and strength. Accuracy and repeatability are almost equal to the taut-band’s, and good performance from the pivot and jewel construction is the reason for its long popularity.
Case: Polycarbonate Plastic – metal casing available for special applications that require extra shielding
Cover: Glass window with black polycarbonate bezel
Damping: Eddy current
Overload:
Continuous 120% of rated value
Short-Term:Current Measurement Moving Coil10 x rated value, 5 s With rectifier:2 x rated value, 0.5 s
Short-Term:Voltage Measurement Moving Coil2 x rated value, 5 s With rectifier:2 x rated value, 0.5 s
Overshoot: ≤5% of scale length
Response time: ≤2 s per DIN EN 60061-1
Power Consumption: Ammeters: 0.4 … 0.6 VAVoltmeters: approx. 4.0 VA
General:
Operating Temp.: -25°C to 65°C (-4 to 149°F)Tropicalized or IP54 sealed units available
Storage Temp: -10 to 55°C (14 to 50°F)
Relative Humidity: 95% (non condensing)
space
pdf_pic Downloads: General Specifcations
base
    mail DEIF website