- Output: SPAN 4-20mA, limiting @ <28mA
- Input: RTD - 100Ω, 2 or 3 wire connection
- Input Span: SRTD: 20ºC min., 500ºC max.
- Burnout Detection: Upscale, Standard
- Supply Voltage: 8-38 VDC polarity protected
- Maximum Load: Rmax = (V supply - 8V)÷ 20 mA
- Ambient Temp.: -20ºC to +70ºC
- Humidity: 0-95% RH, non-condensing
- Linearity: RTD: Better than ± .05% of SPAN referred to sensor temperature
- Stability: (for both ZERO and SPAN) RTD (100ºC SPAN): .03% of SPAN/ºC
- Accuracy: 0.1% of SPAN typical
|
|
|
| |
| |
|
|
| |
| |
The Conax Model HPT is a low cost, 2-wire, non-isolated temperature transmitter for RTD sensors, and is designed to fit in our popular T11 model terminal head.
The HPT housing has a removable base allowing access to the electronics for the purpose of temperature range changes, which are easily accomplished with plug-in resistors |
|
| |
| |
|
|
| |
| |
|
|