| The termination shown above is the Conax Buffalo Type “C.” This lightweight head provides a convenient and compact method of terminating thermocouple wires and connecting cold end leads. Screw posts, mounted in high purity alumina, securely fasten leadwires in position.
The TG gland has an operational temperature range of –300°F to 1600°F (–185°C to +870°C); pressure range up to 10,000 PSI @68°F (690 bar @ 20°C). Both parameters are dependent upon the installed sealant material type. |