.jpg) |
|
|
|
| |
|
| |
|
|
| |
| |
|
|
|
|
| |
| |
- Output Power: 500 VA to 1kVA (for larger 1-phase sizes up to 40kVA see the APS 1000 Series)
- Output Frequency: 45-500 Hz
- Output Voltage: Dual range, 0-150 V or 0-300 V, 1 phase
- Isolated Linear Output, THD: 0.5%
- Input Requirements: 115 VAC or 230 VAC, 1 phase, 47-63 Hz
- Intuitive Front Panel Controls: Frequency, Voltage & Current Limit
- Easy to Read LED Displays: Frequency, Voltage, Current and Power or Power Factor
- Memory Locations: Can save three desired settings of any voltage, frequency and current limit covered in the output parameters
- Power Outlets: Universal Domestic and International Connectors
- Option: PLC Remote Interface which includes 7 memory locations
|
|
| |
| |
|
|
|
| |
| |
The FC200 series consists of two 1 phase output instruments
i with an output power of 500VA or 1kVA. These converters have a range of 45-500Hz with dual voltage ranges
from 0-150 volts or 0-300 volts. This allows the user to duplicate a 50 or 60 hertz
a utility grid and the ability to range up to 400 Hertz for
testing military/avionics electronics and instruments.
Setup and operation of the FC 200 Series is exceptionally
easy. It is set via the front panel, allowing users to
continuously adjust voltage and frequency or to select
preset standard frequency settings. Universal power
outlets are provided on the front panel for ready access
to the controlled power.
Frequency, voltage, current, power or power factor are displayed on large LED Displays. |
|
| |
| |
|
|
|
| |
| |
| Model |
FC205 |
FC210 |
Input Specifications |
| Input Phase |
1-phase / 2-wire + Ground |
| Input Voltage |
115/230Vac ± 15% |
| Output Specifications |
| Power Rating |
|
500VA |
1000VA |
| Max Arms |
0-150V |
4.2A |
8.4A |
| 0-300V |
2.1A |
4.2A |
| Phase |
1-phase / 2-wire + Ground |
| Voltage (r.m.s.) |
Low Range |
0-150V |
| High Range |
0-300V |
| Resolution |
0.1V |
| Accuracy |
±
(0.5% of setting + 2 counts) |
| Frequency |
Range |
45 - 500Hz |
| Resolution |
0.1Hz at 45 - 99.9Hz, 1Hz at 100 - 500Hz |
| Accuracy |
± 0.2% |
| Harmonic Distortion |
≤ 0.5% (Resistive Load) |
| Crest Factor |
≥ 4 to 1 |
| Load Regulation |
±0.5% (Resistive Load) |
| Protection |
Over-Current, Short-Circuit, Over-Temperature |
| Operating Temperature |
32°F - 104°F (0°C - 40°C), 80% Relative Humidity |
| Altitude |
Below 6,500 Feet |
| Display and Controls |
| 4 Digital LED meters |
Frequency, Voltage, Current, Power or Power Factor (simultaneously) |
| Memory (Standard) |
3 Memories, 3 Programmable Parameters per Memory for:
Voltage, Frequency, Current Limit |
| Calibration |
Front Panel Calibration |
| Auto-Voltage Adjust |
Provides improved voltage regulation to within ± 0.1V |
| Mechanical Specifications |
| Power Rating |
|
500VA |
1000VA |
| Dimensions (H/W/D) |
(in) |
3.5/16/17 |
3.5/22/17 |
| (mm) |
89/406/432 |
89/559/432 |
| Weight |
(lbs.) |
48 |
81 |
| (kg.) |
22 |
37 |
|
|
| |
| |
|
|
|
| |
| |
Specifications |
|
|
|
 |
| |
 |
|
|