.jpg) |
|
|
|
| |
|
| |
|
|
| |
|
|
|
|
| |
| |
- Internet ready-web accessible
HTTP Web page browse, email sending on time interval or on event
- True-RMS measuring parameter
- 4-quadrant Energy
- Power Quality Analysis
- Over range alarm
- Energy pulse output
Metering
- Voltage V1, V2, V3, Vlnavg, V12, V23, V31, Vllavg
- Current I1, I2, I3, In, Iavg
- Power P1, P2, P3, Psum
- Reactive Power Q1, Q2, Q3, Qsum
- Apparent Power S1, S2, S3, Ssum
- Frequency F
- Power Factor PF1, PF2, PF3, PF
- Energy Ep_imp, Ep_exp, Ep_total, Ep_net
- Reactive Energy Eq_imp, Eq_exp, Eq_total, Eq_net
- Apparent Energy Es
- Demand Dmd_P, Dmd_Q, Dmd_S
Monitoring
- Power Quality
- Voltage Harmonics 2nd to 31st and THD
- Current Harmonics 2nd to 31st and THD
- Voltage Crest Factor
- THFF (TIF)
- Current K Factor
- Voltage Unbalance Factor U_unbl
- Current Unbalance Factor I_unbl
- Max/Min Statistics with Time Stamps
Alarms
- Limits can be set for up to 16 indicated parameters and can be set with a specified time interval. If any input of the indicated parameters is over or under its setting limit and persists over the specified time interval, the event will be recorded with time stamps and trigger the Alarm DO output. The 16 indicated parameters can be selected from any of the 44 parameters available.
I/O option module
- The E-module® adds flexibility and easy
expansion of the I/O function of Acuvim II. A maximum of 3
modules can be used for one meter. Digital input, digital output,
pulse output, relay output, analog input and analog output are
provided by I/O option module.
Display
- Clear and large character LCD Screen display with white back light
Wide environmental temperature endurance
Display Load percentage, 4 quadrants power and load nature
|
|
|
| |
| |
|
|
|
|
| |
| |
- Metering of distribution feeders, transformers, generators,
capacitor banks and motors
- Medium and low voltage systems
- Commercial, industrial, utility
- Power quality analysis
|
|
|
| |
| |
|
|
|
| |

|
| The Acuvim II is a high-end multifunction panel mount, power meter, an ideal choice for monitoring and controlling
of power distribution systems.
Acuvim II may be used to gather data from intelligent
Power Distribution Systems . All Data can be accessed via 485 communication
port running Modbus™ Protocol. Optional Ethernet , Profibus DP
communication and wireless
transmission add flexibility to all your application needs. |
|
|
| |
| |
|
|
|
| |
| |
| Metering |
| Parameters |
Accuracy |
Resolution |
Range |
Voltage |
0.2% |
0.1V |
20V~500kV |
| Current |
0.2% |
0.001A |
5mA~50000A |
| Current Demand |
0.5% |
1W |
-9999MW~9999MW |
| Power |
0.5% |
1Var |
-9999MVar~9999MVar |
| Reactive Power |
0.5% |
1VA |
-9999MVA~9999MVA |
| Apparent Power |
0.5% |
1W |
-9999MW~9999MW |
| Power Demand |
0.5% |
1Var |
-9999MVar~9999MVar |
| Reactive Power |
0.5% |
1VA |
-9999MVA~9999MVA |
| Power Factor |
0.5% |
0.001 |
-1.000~1.000 |
| Frequency |
2.0% |
0.01Hz |
45.00~65.00Hz |
| Energy |
Primary |
0.5% |
0.1kWh |
0-99999999.9kWh |
| Secondary |
0.5% |
0.001kWh |
0-999999.999kWh |
| Reactive Energy |
Primary |
0.5% |
0.1kvarh |
0-99999999.9kVarh |
| Secondary |
0.5% |
0.001kvarh |
0-999999.999kVarh |
| Apparent Energy |
Primary |
0.5% |
0.1kVAh |
0-99999999.9kVAh |
| Secondary |
0.5% |
0.001kVAh |
0-999999.999kVAh |
| Harmonics |
2.0% |
0.1% |
0.0%~100.0% |
| Phase Angle |
2.0% |
0.1° |
0.0°~359.9° |
| Imbalace Factor |
2.0% |
0.1%
|
0.0%~100.0% |
| Running Time |
|
0.01h |
0~9999999.99h |
| Comminications |
| RS-485 (Option) |
MODBUS RTU Protocol
2-wire connection,
Up to 38400 baud rate |
| Ethernet (Optional) |
10M/100M BaseT
MODBUS TCP/IP Protocol
Data Browsing through HTTP
Sending e-mail automatically |
| PROFI-BUS (Optional) |
PROFIBUS-DP/V0 Protocol
PROFIBUS slave, baud rate adaptive to 12M
Typical input bytes: 32, typical output bytes: 32
PROFIBUS standard according to EN 50170 vol.2 |
|
|
| |
|||||||| Click here for Input, Control Power, Output Specifications
| Input |
| Current Inputs (Each Channel) |
| Nominal Current |
5 AAC |
| Metering Range |
0~10 A ac |
| Withstand |
100Arms for 1 second, non-recurring 3250VAC, 50/60Hz for 1 minute |
| Burden |
0.05VA (typical) @ 5Arms |
| Pickup Current |
0.1% of nominal |
| Accuracy |
0.2% full scale |
| Voltage Inputs (Each Channel) |
| Nominal Full Scale |
400Vac L-N, 690Vac L-L
|
| Withstand |
1500VAC continuous |
| Input Impedance |
3250Vac, 50/60Hz for 1minute |
| Metering |
2Mohm per phase |
| Frequency |
45Hz~65Hz |
| Pickup Voltage |
10VAC |
| Accuracy |
0.2% full scale |
| Harmonic Resolution |
Active
|
IEC 62053-22 |
class 0.5S |
| Reactive |
IEC 62053-23 |
class 2 |
| Harmonic Resolution |
| Metered Value |
31st harmonics |
| Control Power |
| |
| Universal |
AC or DC |
| AC/DC Control Power |
| Operating Range |
100~415Vac, 50/60Hz; 100~300Vdc |
| Burden |
5VA typical |
| Frequency |
40Hz~70Hz |
| Withstand |
3250Vac, 50/60Hz for 1 minute |
| DC Control Power |
| Operating Range |
100~370Vdc (±10%) |
| Burden |
3W typical, 5W maximum |
| Low Voltage DC Control Power (Optional) |
| Operating Range |
20~60Vdc (±10%) |
| Burden |
2.5W typical, 4W maximum |
|
| |
|||||||| Click here for I/O option
| I/O option |
| Digital Input |
| Input Voltage Range |
20~250 VAC/DC |
| Input Current (Max) |
2mA |
| Start Voltage |
15V |
| Stop Voltage |
5V |
| Pulse Frequency (Max) |
100Hz, 50% Duty Ratio (5ms ON and 5ms OFF)
|
| SOE Resolution |
2ms |
| Digital Output (DO) (Photo-MOS) |
| Voltage Range |
0~250 VAC/DC |
| Load Current |
100mA (Max) |
| Output Frequency |
25Hz, 50% Duty Ratio (20ms ON, 20ms OFF)
|
| Isolation Voltage |
2500V |
| Relay Output (RO) |
| Switching Voltage (Max) |
250 VAC, 30VDC |
| Load Current |
3A |
| Set Time |
10ms (Max) |
| Contact Resistance |
100mΩ (Max) |
| Isolation Voltage |
2500V
|
| Mechanical Life |
1.5x107 |
| Analog Output (AO) |
| Output Range |
0~5V/1~5V, 0~20mA/4~20mA (Optional) |
| Accuracy |
0.5% |
| Temperature Drift |
50ppm/°C typical
|
| Isolation Voltage |
500V |
| Open Circuit Voltage |
15V |
| Analog Input (AI) |
| Input Range |
0~5V/1~5V, 0~20mA/4~20mA (Optional) |
| Accuracy |
0.2% |
| Temperature Drift |
50ppm/°C typical |
| Isolation Voltage |
500V |
| Power Supply for DI (24Vdc) |
| Output Voltage |
24 VDC |
| Output Current |
42mA |
| Load (Max) |
21DIs |
|
| |
|||||||| Click here for Operating Specifications, Size and Compliance
| Standard Compliance |
| General |
| USA |
UL 61010-1 |
| Canada |
cUL 61010-1 |
| Europe |
IEC 61010-1 |
| Emission |
| Radiated/Conducted |
FCC Part 15 Subpart B, Class A |
| Radiated/Conducted |
EN 55011 |
| Harmonic |
IEC 61000-3-2 |
| Voltage Fluctuation |
IEC 61000-3-3 |
| Radio Interference |
EN 50081-2 |
| Immunity |
| Electromagnetic |
IEC 61000-6-2 |
| Compatibility |
IEC 61000-4-2 |
| ESD |
Radiated, radio-frequency,
electromagnetic field |
IEC 61000-4-3 |
| Electrical fast transient/burst |
IEC 61000-4-4 |
| Surge |
IEC 61000-4-5 |
| Conducted disturbances |
IEC 61000-4-6 |
| Power frequency magnetic field |
IEC 61000-4-8 |
| Voltage dips and interruptions |
IEC 61000-4-11 |
| Generic Immunity Standard for Industrial Environment |
EN 50082-2 |
| Operating Environment |
| General |
|
| Operation Temp. |
- 25ºC to 70ºC |
Storage Temp.
|
- 40ºC to 85ºC |
| Relative Humidity |
5% to 95% non-condensing |
| Pollution Degree |
2 |
| Dimensions |
| Size |
96 x 96 x 51 (92 x 92 Cutout)
DIN or 4’’ ANSI Round |
|
| |
| |
|
|
|
| |
| |
Specifications |
|
|
|
 |
| |
 |
|
 |
|