- True-RMS measuring parameter
- 4-quadrant Energy
- Power Quality Analysis
- Over range alarm
- Energy pulse output
Metering
- Voltage V1, V2, V3, V12, V23, V31
- Current I1, I2, I3, In
- Power P1, P2, P3, Psum
- Reactive Power Q1, Q2, Q3, Qsum
- Apparent Power Ssum
- Frequency F
- Power Factor PF1, PF2, PF3, PF
- Energy Ep_imp, Ep_exp
- Reactive Energy Eq_imp, Eq_exp
- Demand Dmd_I1, Dmd_I2, Dmd_I3, Dmd_P, Dmd_q
Monitoring
- Power Quality
- Voltage Harmonics 2nd to 15th and THD
- Current Harmonics 2nd to 15th and THD
- Voltage Imbalance Factor U_unbl
- Current Imbalance Factor I_unbl
- Max/Min Statistics with Time Stamps
- Running Hour
Alarms
- One (1) alarm parameter may be set within a specified time interval.
If indicated parameter is over or under its setting limit and persists
over the specified time interval, the event will be recorded with time
stamps and trigger the Alarm DO output. The indicated parameter
can be selected from any of the 31 parameters available.
Pulse Output option
- Two Digital outputs can be configured as pulse output for kWh and
kVarh. The pulse rate and width can be set.
Display
- Clear and large character LCD Screen display with orange back light
Wide environmental temperature endurance
|
|
|
| |
| |
|
|
|
|
| |
| |
- Metering of distribution feeders, transformers, generators,
capacitor banks and motors
- Medium and low voltage systems
- Commercial, industrial, utility
- Power quality analysis
|
|
|
| |
| |
|
|
|
| |

|
| The Acuvim-L series are the ideal choice for monitoring and controlling
power distribution systems.
Acuvim-L may be used to gather data from intelligent
Power Distribution Systems . All Data can be accessed via 485 communication
port running Modbus™ Protocol. Optional Ethernet, Profibus DP
communication and wireless
transmission add flexibility to all your application needs.
The quality of your power system is important with increasing use of
electronic loads such as computers, ballasts or variable frequency
drives. With the Acuvim-L power analysis option, any phase current
or voltage can be displayed and the harmonic content calculated.
By knowing the harmonic distribution, action can be taken to
prevent overheated transformers, motors, capacitors, neutral wires
and nuisance breaker trips. Redistribution of the system loading can
also be determined. |
|
|
| |
| |
|
|
|
| |
| |
| Metering |
| Parameters |
Accuracy |
Resolution |
Range |
Voltage |
0.5% |
0.1V |
20V~500kV |
| Current |
0.5% |
0.02% |
0~50000A |
| Current Demand |
0.5% |
0.02% |
0~50000A |
| Power |
1.0% |
0.1% |
-4294MW~4294MW |
| Reactive Power |
1.0% |
0.1% |
-4294MVar~4294MVar |
| Apparent Power |
1.0% |
0.1% |
0~4294MVA |
| Power Demand |
1.0% |
0.1% |
0~4294MW |
| Reactive Power |
1.0% |
0.1% |
0~4294MVar |
| Power Factor |
1.0% |
0.1% |
-1.0~1.0 |
| Frequency |
0.2% |
0.01Hz |
45~65Hz |
| Energy |
1.0% |
0.1kWh |
0~99999999.9kWh |
| Reactive Energy |
1.0% |
0.1kvarh |
0~99999999.9kVarh |
| Harmonics |
2.0% |
0.1% |
0~100.0% |
| Running Time |
|
0.1h |
0~9999999.99h |
| Comminications |
<
| RS-485 (Option) |
MODBUS RTU Protocol
2-wire connection, Half-duplex, Isolated1200 to 38400 baud rate |
|
|
| |
|||||||| Click here for Input, Control Power and Output Specifications
| Input |
| Current Inputs (Each Channel) |
| Nominal Current |
5 AAC |
| Metering Range |
0~6 AAC |
| Withstand |
100Arms for 1 second, non-recurring 3250VAC, 50/60Hz for 1 minute |
| Burden |
0.05VA (typical) @ 5Arms |
| Pickup Current |
0.1% of nominal |
| Accuracy |
0.2% full scale |
| Voltage Inputs (Each Channel) |
| Nominal Full Scale |
400Vac L-N, 690Vac L-L
|
| Withstand |
1500VAC continuous |
| Input Impedance |
3250Vac, 50/60Hz for 1minute |
| Metering |
2Mohm per phase |
| Frequency |
45Hz~65Hz |
| Pickup Voltage |
10VAC |
| Accuracy |
0.2% full scale |
| Harmonic Resolution |
Active
|
IEC 62053-22 |
class 1 |
| Reactive |
IEC 62053-23 |
class 3 |
| Harmonic Resolution |
| Metered Value |
15th harmonics |
| Control Power |
| |
| Universal |
AC or DC |
| AC/DC Control Power |
| Operating Range |
100~415VAC (±10%) |
| Burden |
5VA typical, 10VA maximum, 6W maximum |
| Frequency |
40Hz~70Hz |
| Withstand |
2500VAC, 50/60Hz for 1 minute |
| DC Control Power |
| Operating Range |
100~370Vdc (±10%) |
| Burden |
3W typical, 5W maximum |
| Low Voltage DC Control Power (Optional) |
| Operating Range |
20~60Vdc (±10%) |
| Burden |
2.5W typical, 4W maximum |
| Digital Output Option |
| Digital Output (DO) (Photo-MOS) |
| Voltage Range |
0~250VAC/DC |
| Load Current |
100mA (Max) |
| Output Frequency |
25Hz, 50% Duty Ratio (20ms ON, 20ms OFF) |
| Isolation Voltage |
2500V |
|
| |
|||||||| Click here for Operating Specifications, Size and Compliance
| Standard Compliance |
| General |
| USA |
UL 61010-1 |
| Canada |
cUL 61010-1 |
| Europe |
IEC 61010-1 |
| Emission |
| Radiated/Conducted |
FCC Part 15 Subpart B, Class A |
| Radiated/Conducted |
EN 55011 |
| Harmonic |
IEC 61000-3-2 |
| Voltage Fluctuation |
IEC 61000-3-3 |
| Radio Interference |
EN 50081-2 |
| Immunity |
| Electromagnetic |
IEC 61000-6-2 |
| Compatibility |
IEC 61000-4-2 |
| ESD |
Radiated, radio-frequency,
electromagnetic field |
IEC 61000-4-3 |
| Electrical fast transient/burst |
IEC 61000-4-4 |
| Surge |
IEC 61000-4-5 |
| Conducted disturbances |
IEC 61000-4-6 |
| Power frequency magnetic field |
IEC 61000-4-8 |
| Voltage dips and interruptions |
IEC 61000-4-11 |
| Generic Immunity Standard for Industrial Environment |
EN 50082-2 |
| Operating Environment |
| General |
|
| Operation Temp. |
- 25ºC to 70ºC |
Storage Temp.
|
- 40ºC to 85ºC |
| Relative Humidity |
5% to 95% non-condensing |
| Pollution Degree |
2 |
| Dimensions |
| Size |
96 x 96 x 51 (92 x 92 Cutout)
DIN or 4’’ ANSI Round |
|
| |
| |
|
|
|
| |
| |
Specifications |
|
|
|
 |
| |
 |
|
 |
|