Spacer Home Contact_us ob Opportunities ISO_Registration Privacy_Statement
 
AC Power Supplies

Associated Power Technologies

Model 6020, AC Power Source
2kVA, 1 Phase-2 Wire Output, 47-500 Hz

 
previous URL Next URL
< Links >
 
 
 
Associated Power Technologies, Model 6020, 2kVA Automated AC Power Source
 
  Characteristics:  
 
 
  • Graphic Liquid Crystal Display
  • Encoder wheel to adjust voltage and frequency during a test
  • Test/reset key to activate and disable output
  • Universal receptacle to handle multiple country configurations
  • RS-232 interface standard – GPIB optional
  • 50 memories with 9 steps per memory
  • PLC output for Pass/Fail/Test-in-Process
  • Prompt feature to add instructions to a test
  • Over current fold back
  • Front panel lockout
  • Enhanced protection circuits
  • Fully programmable parameters high/low limits for voltage, amps and frequency
  • Programmable test time, delay time, and ramp timers
  • Programmable surge/drop voltage, start/end angle
 
 
  Product Description:  
 
  The 6020 is a full featured switching 2kVA AC power source. This programmable power source comes standard with a RS-232 interface for computer control or with optional GPIB. The 6020 provides variable output voltage from 0-300 V and output frequencies from 40-500 Hz. The input voltage is 208 V with an input frequency from 47-500 Hz. The 6020 AC power source includes a graphic liquid crystal display that enables the operator to monitor voltage, frequency, current, peak current, power, and power factor simultaneously. Each parameter can be programmed independently along with other parameters such as ramping of voltage, testing time, as well as high & low limits. The 6020 AC power source also provides 50 programmable memories with 9 steps for connecting routines. A lockout feature is also available to protect pre-programmed routines.

The 6020 AC power source offers enhanced features which are ideal for a variety of power applications. The front panel rotary knob allows for instant adjustments of voltage and frequency while testing. The operator also has control of the start/end angle of the wave form, along with programming surge/drop cycles. Additionally, the operator can program the unit for an auto looping cycle and auto run mode which is ideal for burn-in/life cycle testing.

 
 
  Specifications:  
 
 
|||||||| Click here for Input and Output Specifications
Model 6020
Input
Phase
Voltage 208 Vac ± 15%
OPTION: 230 Vac ± 10%
Frequency 47 - 500 Hz
Output
Power Rating 2000 VA
Max. Current (RMS) 0 - 150 V: 18.4 A Low Range
0 - 300 V: 9.2 A High Range
Frequency Range: 40 - 500 Hz
Phase 1 Ø/2 W
Total Harmonic
Distortion (T.H.D)
< 0.5% at 40 - 100 Hz
< 1% at 101 - 450 Hz
(Resistive Load)
Crest Factor ≥ 3
Line Regulation ± 0.1 V
Load Regulation ± (0.5% of output +0.5 V)
at Resistive Load
Response Time < 400 μ/sec

|||||||| Click here for Measurement Specifications
Measurement
Voltage Range: 0.0 - 400.0 V
Resolution: 0.1 V
Accuracy: ± (1% of reading +2 counts)
Frequency Range: 0.0 - 500.0 Hz
Resolution:
0.1 Hz
Accuracy: ± 0.1 Hz
Current (rms) Range: 0.005 - 26.00 A
Resolution:
Low Range: 0.001 A
High Range: 0.01 A
Accuracy: ± (1% of reading +5 counts)
Current (peak) Range: 0.0 - 76.0 A
Resolution:
0.1 A
Accuracy: ± (1% of reading +5 counts)
Power Range: 0.0 - 2600 W
Resolution:
Low Range: 0.1 W
High Range: 1 W
Accuracy: ± (2% of reading +2 counts)
Power Factor Range: 0.000 - 1.000
Resolution: 0.001
Accuracy: W/VA, Calculated and displayed to three significant digits
Inrush Current 4 times the rated current
Enhanced OverLoad Capacity 4 times the rated current,
Short Circuit hold for 1000 ms

|||||||| Click here for Setting Specifications
Settings
Remote Input Signal
Interface (Option)
Test, Reset, Recall memory
1 through 7
Remote Output Signal Pass, Fail, Test-in-Process
Surge/Drop Voltage Selectable On/Off
Auto Run Mode
Selection
Program/Manual
Sync Output Signal DC Level 5 V
Timer 0 = Continuous, 0.1 - 999.9
Alarm Volume Setting Range: 0 - 9; 0 = OFF
Auto Loop Cycle 0 = Continuous, 1 = OFF, 0 - 9999
Over Current Fold
Back Mode
On/Off Setting < 700 ms
Single Step On/Off Setting
Contrast Range: 1 - 9
Power Up Selectable On, Off, Last
Timer Units Selectable Second, Minute, Hour
Hi & Lo Volt Adjustable 0 - 300 V
Hi & Lo Frequency Adjustable 40 - 500 Hz
End & Start Angle Adjustable 0 - 359°
Results Selectable All, Pass/Fail, Last

|||||||| Click here for General Specifications
General
Memory 50 memories, 9 steps/memory
High/Low Limit
Protection
Arms, Apeak, P, PF
Protection Over Current Protection, Over Voltage
Protection, Over Power Protection,
Over Temperature Protection, Alarm
Interface (Option) GPIB/RS232, PLC Remote
Input Card
Calibration Front Panel Calibration
Efficiency ≥ 80% (at Full Load)
Operation
Environment
0 - 40°C/20 - 80% RH
Mechanical
Front Panel Output Built-in Cooling Fan
Rear Panel Output Universal Receptacle
Dimension (WxHxD, mm) 430 x 89 x 500
Net Weight 68 lbs
 
 
 
  pdf_pic Downloads: Specifications  
base
 
 
Scroll down
 
scroll
 
  scroll up  
 
index mail web