|
.jpg) |
|
|
|
| |
|
| |
|
|
| |
|
|
|
|
| |
| |
- Graphic Liquid Crystal Display
- Encoder wheel to adjust voltage and frequency during a test
- Test/reset key to activate and disable output
- Universal receptacle to handle multiple
country configurations
- RS-232 interface standard – GPIB optional
- 50 memories with 9 steps per memory
- PLC output for Pass/Fail/Test-in-Process
- Prompt feature to add instructions to a test
- Over current fold back
- Front panel lockout
- Enhanced protection circuits
- Fully programmable parameters high/low limits for voltage,
amps and frequency
- Programmable test time, delay time, and ramp timers
- Programmable surge/drop voltage, start/end angle
|
|
| |
| |
|
|
|
| |
| |
The 6010 is a full featured switching 1kVA AC power source. This programmable power source comes standard with a RS-232 interface for computer control or with optional GPIB. The 6010 provides variable output voltage from 0-300 V and output frequencies from 40-500 Hz. The input voltage is selectable between 115/230 with an input frequency from 47-500 Hz. The 6010 AC power source includes a graphic liquid crystal display that enables the operator to monitor voltage, frequency, current, peak current, power, and power factor simultaneously. Each parameter can be programmed independently along with other parameters such as ramping of voltage, testing time, as well as high & low limits. The 6010 AC power source also provides 50 programmable memories with 9 steps for connecting routines. A lockout feature is also available to protect pre-programmed routines.
The 6010 AC power source offers enhanced features which are ideal for a variety of power applications. The front panel rotary knob allows for instant adjustments of voltage and frequency while testing. The operator also has control of the start/end angle of the wave form, along with programming surge/drop cycles. Additionally, the operator can program the unit for an auto looping cycle and auto run mode which is ideal for burn-in/life cycle testing.
|
|
| |
| |
|
|
|
| |
| |
|||||||| Click here for Input and Output Specifications
| Model 6010 |
| Input |
| Phase |
1Ø |
| Voltage |
208 Vac ± 15%
OPTION: 230 Vac ± 10% |
| Frequency |
47 - 500 Hz |
| Output |
| Power Rating |
1000 VA |
| Max. Current (RMS) |
0 - 150 V: 9.2 A Low Range
0 - 300 V: 4.6 A High Range |
| Frequency |
Range: 40 - 500 Hz |
| Phase |
1 Ø/2 W |
Total Harmonic
Distortion (T.H.D) |
< 0.5% at 40 - 100 Hz
< 1% at 101 - 450 Hz
(Resistive Load) |
| Crest Factor |
≥ 3 |
| Line Regulation |
± 0.1 V |
| Load Regulation |
± (0.5% of output +0.5 V)
at Resistive Load |
| Response Time |
< 400 μ/sec |
|||||||| Click here for Measurement Specifications
| Measurement |
| Voltage |
Range: 0.0 - 400.0 V
Resolution: 0.1 V
Accuracy: ± (1% of reading +2 counts) |
| Frequency |
Range: 0.0 - 500.0 Hz
Resolution:
0.1 Hz
Accuracy: ± 0.1 Hz |
| Current (rms) |
Range: 0.005 - 13.00 A
Resolution:
Low Range: 0.001 A
High Range: 0.01 A
Accuracy: ± (1% of reading +5 counts) |
| Current (peak) |
Range: 0.0 - 38.0 A
Resolution:
0.1 A
Accuracy: ± (1% of reading +5 counts) |
| Power |
Range: 0.0 - 1300W
Resolution:
Low Range: 0.1W
High Range: 1W
Accuracy: ± (2% of reading +2 counts) |
| Power Factor |
Range: 0.000 - 1.000
Resolution: 0.001
Accuracy: W/VA, Calculated and displayed to three significant digits |
| Inrush Current |
4 times the rated current |
| Enhanced OverLoad Capacity |
4 times the rated current,
Short Circuit hold for 1000 ms |
|||||||| Click here for Setting Specifications
| Settings |
Remote Input Signal
Interface (Option) |
Test, Reset, Recall memory
1 through 7 |
| Remote Output Signal |
Pass, Fail, Test-in-Process |
| Surge/Drop Voltage |
Selectable On/Off |
Auto Run Mode
Selection |
Program/Manual |
| Sync Output Signal |
DC Level 5 V |
| Timer |
0 = Continuous, 0.1 - 999.9 |
| Alarm Volume Setting |
Range: 0 - 9; 0 = OFF |
| Auto Loop Cycle |
0 = Continuous, 1 = OFF, 0 - 9999 |
Over Current Fold
Back Mode |
On/Off Setting < 700 ms |
| Single Step |
On/Off Setting |
| Contrast |
Range: 1 - 9 |
| Power Up |
Selectable On, Off, Last |
| Timer Units |
Selectable Second, Minute, Hour |
| Hi & Lo Volt |
Adjustable 0 - 300 V |
| Hi & Lo Frequency |
Adjustable 40 - 500 Hz |
| End & Start Angle |
Adjustable 0 - 359° |
| Results |
Selectable All, Pass/Fail, Last |
|||||||| Click here for General Specifications
| General |
| Memory |
50 memories, 9 steps/memory |
High/Low Limit
Protection |
Arms, Apeak, P, PF |
| Protection |
Over Current Protection, Over Voltage
Protection, Over Power Protection,
Over Temperature Protection, Alarm |
| Interface (Option) |
GPIB/RS232, PLC Remote
Input Card |
| Calibration |
Front Panel Calibration |
| Efficiency |
≥ 80% (at Full Load) |
Operation
Environment |
0 - 40°C/20 - 80% RH |
| Mechanical |
| Front Panel Output |
Built-in Cooling Fan |
| Rear Panel Output |
Universal Receptacle |
| Dimension (WxHxD, mm) |
430 x 89 x 400 |
| Net Weight |
42 lbs |
|
|
| |
|
|
| |
| |
Specifications |
|
|
|
 |
| |
 |
| |
Related urls:
|
|
|
| |
Manual AC Power Sources |
Automated AC Power Sources |
| |
|
|
| |
|
| |
|
|
|
|
|