SOFTWARE
The Ethernet interface and its web
server offer new ways of working and
communicating, local or remote, with a
convenience and effectiveness that will
quickly make them necessities. All that is
needed for communication is that the
other equipment (printer, PC, etc.) has an
IP address. Thus, even on the road, you
can print results on a network printer,
exchange files between the OX 7100
series oscilloscopes and a computer.
You can also monitor the instrument
remotely from any PC, display the traces
in real-time and control it using the
instrument panel. Whether locally or at
a distance, these transfer and exchange
operations are simple and rapid and do
not require special software on the
computer, thanks to the web server.
The PROBIX
system is your
assurance that using the
instrument will not only be rapid but also,
more importantly, error-free, which is critical for devices
used for troubleshooting. For unfailing compatibility, the connection of BNC connectors or
standard test leads is accomplished using the safety adapters provided. An interchangeable
plastic ring can be used to match the color of the accessory to the color of its channel. Power is
supplied and the sensors are calibrated directly from the oscilloscope. Some accessories have
three control buttons accessible on the probe itself.
Configuration of the channels and
management of the sensors:
The coefficients, scales and units of the sensors and the channel
configurations are managed automatically. The first two control
buttons on the probes are used to directly modify the adjustment
parameters of the channel to which they are connected or to copy
functions from the front panel of the oscilloscope. The third button is
specific to the accessory. On voltage probes, for example, it controls
the lighting of the measurement area. When the connection is made,
all preferred parameters stored in the accessories (assignments of
buttons one and two, color) are automatically reactivated. They can
be modified using the Probix "pop-up" shown to the right.
Automatic recognition of sensors
and connection accessories:
Probix probes and adapters are plug-and-play and are recognized
immediately when connected. The instrument not only identifies them,
but also configures to their characteristics. Active safety is built in,
notably in the form of safety information and recommendations
concerning the accessory used. A pop-up screen displays:
• the maximum input voltage
• the maximum voltage to ground
• the maximum voltage between channels
• the type of sensor being used
• the use of a suitable safety lead |
|
|
|
|
| |
|
| |
|
| |
|
| |
| |
- Isolated inputs: 600VAC, 850VDC to ground and channel-to-channel
- Five complementary tools in one: Oscilloscope, Multimeter,
- FFT Analyzer, Harmonic Analyzer and Recorder
- 12-bit resolution provides deeper accurate zooming
- Sampling rate 1GS/s in one-shot and 25GS/s in ETS with memory depth
- of 2500 counts per channel in “oscilloscope” mode
- Four independent, 8000-count,TRMS, 45kHz, digital multimeters
- Color LCD with touch screen functions
- 33 direct command keys and “Windows-like” menus on screen
- Multi-interface communication connector: RS-232, Centronics and
Ethernet with web server
- Plug-and-play self-identifying and calibrating input probes and accessories Kit
- SX-METRO-P Software, Data Retrieval Processing
Cat. #2124.70
- Grip Probes — set of two, color-coded (red/black)
Cat. #2124.86
- Straight — Ethernet Cable
Cat. #2124.80
- Small Classic Tool Bag
Cat. #2133.72
- PROBIX Current Probe, 20mA-20A, 100kHz
Cat. #2124.77
- PROBIX PRHX7 K Thermocouple Adapter
Cat. #2124.78
- Leads — set of two, color-coded 1.5m (red/black
4mm straight, 4mm right angle) with color-coded
Safety Alligator Clips (red/black)
Cat. #2124.84
|
|
|
|
| |
| |
|
|
|
|
| |
| |
- On-site contractor maintenance – industrial or electronic
- “Internal” plant maintenance
- Installations and start-up
- Industrial Process
- Quality control
- Research and laboratory – engineers or technicians
|
|
| |
| |
|
|
|
| |
 |
The Model OX 7104-C is the perfect tool for both laboratory and field testing.
Ease-of-use of the instrument is facilitated through 33 specialized keys for direct access to commonly used functions. Ideal for field use, the Model OX 7104-C utilizes the patented new system of plug-and-play accessories, individual isolation of each of the measurement channels, a range of remote management capabilities based on an Ethernet link with web server, a number of built-in instruments, including a four channel TRMS multimeter.
The large 320 x 240 full color LCD screen provides detailed graphical and alphanumerical representations of all measurements and also functions as a touch screen. Using the convenient stylus, the various “Windows-like” menus can be opened or pulled down and executed. The stylus can also be used for direct action on graphic elements such as cursors, triggers, zooming, etc.
|
|
|
| |
| |
|
|
|
|
| |

|
- Comprehensive triggering functions to
record only what is necessary
The AEMC® Instruments OX 7100 series are the first
oscilloscopes in this category to offer sophisticated triggering
functions that go beyond primary triggering on a front,
or even on a pulse duration. The delay mode allows
observation of any event with maximum resolution,
even if it occurs long after the actual triggering. For
example, the counting mode makes it possible to count
events prior to triggering, in order to check the content
of digital frames. Triggering can also be associated
with a TV signal.
- Complete automatic measurements
for precise analysis
The automatic measurements window displays up to
18 parameters for any signal. For a clear analysis, two markers
identify the portion of the signal where the first automatic
measurement was made. A specific measurement zone can
then be selected by outlining it with manual cursors, for a reliable
and more precise result. A direct comparison of two waveforms
is performed by checking "variation from reference memory",
in order to display up to18 parameters of the signal as
differences from the reference.
- Math functions
In oscilloscope mode, the math functions (1, 2, 3 and 4) can be used on each trace to define a mathematical
function and vertical scaling in actual physical unit(s). The real-time on-screen display capability of the
mathematical editor presents four calculated trace results, on which all cursor-selected and automatic
measurements are available. It is therefore possible to examine waveforms as power, for example (V x I),
and make all associated measurements. Many math functions are available, for example +, -, x, /, as well as
sine, cosine, exponent, logarithm, square root, etc., giving access to your exact application.
- Real-time Fast Fourier Transform (FFT) for frequency analysis
The FFT is used to calculate, at 2,500 points, the discrete representation of a signal in the frequency domain from its
representation in the time domain. It is a powerful means to effectively diagnose and analyze signal quality:
- Measurement of the various harmonics and distortion of a signal
- Analysis of impulse response
- The search for a noise source in logical circuits and much more
Several weighting windows are available including Rectangle, Hanning, Hamming and Blackman, along with
two representation modes, linear and logarithmic (scale in dB). The two cursors can then be used to make precise
measurements of frequency spikes, levels, and attenuations, taking advantage of the 80dB dynamic range allowed
by the 12-bit / 1-GS/s conversion. The autoset makes it easier to obtain an optimum spectral representation on
which a graphic zoom can be applied in order to analyze all details of the spectrum.
- TRMS Digital Multimeter
Pressing the meter key gives access to the multimeter function. The Model OX 7104 includes a four-channel
TRMS digital multimeter where the Model OX 7102 includes a two-channel digital multimeter – the basic
instruments for all diagnostics – measures amplitude (AC and DC voltage and current, power, thermocouples, etc.),
resistance, continuity, capacitance and to test components. The PT 100 configuration can be used to measure a
temperature based on 100Ω resistive RTD. All sensors used can be scaled to their true physical unit for optimum
application efficiency.
- Harmonic Analyzer (optional)
Harmonic analysis is a basic function for all users in the fields of power distribution, electrical engineering and
power electronics. With the optional Harmonic Analysis firmware installed, the Model OX 7104-CK can display
harmonics up to the 31st for signals having fundamental frequencies between 40 and 450Hz. Harmonic analysis
can be displayed on all channels simultaneously, in real-time.
- High-Speed Digital Recorder (optional)
For users who must track variations of physical or mechanical phenomena, a high-speed digital recorder, with
sample rates as fast as 800μs and recording times up to one month, can be incorporated into the instrument.
The Recorder offers the ability to monitor thresholds and tolerance windows with triggering of long-term storage
of the phenomenon observed and the automatic capture of successive time-stamped faults (510 defaults and
up to 127,5000 samples). Analysis can be performed on the instrument itself (even mathematical calculations
using values from more than one channel) or standard ".TXT" files exported to a spreadsheet.
|
|
| |
| |
|
|
|
| |
| |
| MODEL |
|
| INTERFACE |
| Screen Specifications |
Color 5.7" LCD (115 x 86mm) 320 x 240 – CCFL backlighting |
| Display Mode |
Vectors with interpolation – 500 samples on screen |
| No. of Traces on Screen |
Four traces and four references – Split screen and full screen modes (tracing zone 110 x 74) |
| Front Panel Control |
32 direct shortcuts |
| Screen Control |
Touch screen – "Windows-like" menus and graphic commands |
| Languages |
Five complete languages, menus and on-line help (English, French, German, Spanish, Italian) |
| VERTICAL |
| Bandwidth |
100MHz |
| Channels |
Four isolated channels |
| Input Impedance |
1MΩ ± 0.5% approx. 17pF |
| Maximum Permanent Input Voltage |
600V Cat. III – Derating -20dB/decade from 100kHz |
| Vertical Sensibility |
16 ranges from 2.5mV to 200V/div |
| Accuracy |
±1.5% |
| Vertical Zoom |
x5 maximum |
| Probe Factors |
1 / 10 / 100 / 1000 or scaling to any value – Definition of the measurement unit |
| HORIZONTAL |
| Time Base Speed |
35 ranges from 1ns/div to 200s/div |
| Accuracy |
±1.5% |
| Horizontal Zoom |
x10 maximum |
| TRIGGERING |
| Mode |
Auto, trigger, single, Auto 50% |
| Source |
CH1, CH2, CH3, CH4 |
| Type |
Front, pulse or delay (40ns/20s), count (2/16384) or TV (525 or 625 lines) |
| Coupling |
AC, DC, HFR, LFR, noise reduction – Hold-off adjustable from 40ns to 1s |
| Sensitivity |
0.6 div to 1KHz / 1.5 div to 150MHz |
| DIGITAL MEMORY |
| Maximum Sampling Speed |
25GS/s in ETS - 1GS/s in one-shot (on each channel) |
| Vertical Resolution |
12 bits |
| Memory Capacity per Channel |
“TRC” approx. 10kB, “TXT” approx. 20kB |
| User Memory |
1MB |
| Other Modes |
Envelope mode (Factors from 2 to 64) |
| XY Mode |
Between two from the four traces – math functions and cursors |
| OTHER FUNCTIONS |
| Autoset |
Complete autoset at less than 3s, with recognition of channels – Frequency > 30Hz |
| FFT Analyzer and Math Functions |
FFT, + , - , x , / - Editor of mathematical functions |
| Cursors |
Two or three cursors : V and T simultaneous or Phase Resolution 12-bit, display four digits |
| Automatic Measurements |
18 level or time measurements, phase measurements – Resolution 12-bit, display four digits |
| MULTIMETER |
| AC, DC, AC + DC voltage |
From 400.0mV to 600VRMS or 800VDC - Accuracy VDC 0.5 % R+ 5D – bandwidth 45kHz |
| Resistance |
80.00 to 32.00M - Precision 0.5 % R+ 25D – Rapid 10-ms continuity test |
| Other Measurements |
Capacities 5.000nF to 5.000mF/Frequency 45kHz – Diode test 3.3V |
| RECORDER (optional) |
| Acquisition Rate |
Sampling interval from 800μs to 18mn approximately |
| Duration of Recording |
From 2s to 31 days |
| Acquisition Mode |
Conditional on thresholds or windows – Normal or "510-faults" acquisition |
| Operation |
Time stamped graphic recording, conversion and units of physical quantities, ) measurement using cursors and search for events, standard file format usable in spreadsheets (.TXT |
| HARMONIC ANALYZER (optional) |
| Analysis Span |
Even or odd orders up to 31, or first 16 orders |
| Operation |
Permanent display: total RMS value and total harmonic distortion – Order selected: % F, phase, freq, VRMS |
| GENERAL SPECIFICATIONS |
| Configurations Memories |
Unlimited – “.CFG” file size approx. 1kB |
| Ethernet Network Printing RS-232 or Centronics (options) |
11 black and white or color drivers : IBM Proprinter, Epson ESC/P, Canon HP PCL, Seiko DPU411,
Postscript Image files: “.BMP” 10kB, “.GIF” approx. 5kB (storage in memory transfer by RS-232 or Ethernet) |
| Communication |
Local via Ethernet 10 MB or RS 232 (option) – Remote via 10 MB Ethernet and web server included
“SX-METRO” application software for PC (option) |
| Power Source |
9.6V/3.8 A/h battery pack – Approx. 4h between charges – Adjustable power-saving switching
Multi-voltage 98-254V / 47-63Hz – Fast charge in two hours (oscilloscope off) |
| Dimensions |
10.25 x 7.25 x 2" (261 x 185 x 53mm) |
| Weight |
4.2 lbs (1.9kg) with batteries |
|
|
| |
| |
|
|
|
| |
| |
Specifications
Comparison Chart |
|
|
|
 |
| |
 |
| |
Related urls: |
|
|
| |
- Model OX7102-C, Portable Oscilloscope (2x100 MHz, Color), [ 2124.50]
- Model OX7102-CK, Portable Scope Kit (2x100 MHz, Color), [ 2124.53]
- Model OX7104-CK, Portable Scope Kit (4x100 MHz, Color), [ 2124.54]
- Model OX7104-C, Port. Scope Power Kit (4x100 MHz, Color), [2124.63]
|
|
| |
|
| |
|
|
|
.jpg) |
|