The Model MX 5EX
is built into a rugged housing
which provides a separate battery and
fuse compartment to isolate the
DMM’s electronics from contamination.
This meter offers a complete set
of measurement ranges and is
in compliance with international
safety and quality standards to
ensure a professional and reliable
measuring tool.
The MX 5EX
measures AC
Amps, AC Volts, DC Amps, DC Volts,
Resistance, Continuity (with beeper)
and has a Diode Test function.
The large and easy-to read LCD
features a 5000-count digital display.
The display features comprehensive
user interface symbols, such as
low battery, Min/Max/Avg and a
34-segment analog bargraph for easy
trend readings. Accuracy is 0.025%.
The meter is equipped with a Data
Hold function that freezes the
measurement for later viewing.
Includes a pair of test leads (red/
black), 9V Alkaline battery, hard
carrying case and a user manual |
|
|
|
|
| |
|
| |
![Model MX57EX [Catalog No. 2130.65] (TRMS, 50,000-count, 0.025% Accuracy)](/Assets/jpgs/AEMC/DMMs/2130.65.jpg) |
- 50,000-count
- ATEX 6005X, EEx ib group I, IIc and temperature class T6 assigned specifications
- Logic signal measurement and ADP input
- MIN/MAX/AVG functions
- Bargraph with zoom (x5) and center zero
- Rugged design - IP67 rating
- Protection by 500mA instrinsic safety fuse for the current range
- Includes test leads
|
|
|
|
| |
|
|
|
|
| |
| |
- Oil refineries
- Mining
- Pharmaceutical plants
|
|
| |
| |
|
|
|
| |
 |
The Model MX57EX is an intrinisically safe digital multimeter designed for use is dangerous or explosive atmospheres. This meter is considered as a passive device without inductive or capacitive issues that are problematic in dangerous or explosive environments. The Model MX57EX provides high functionality in a unique case designed for enhanced safety, reliability, ease-of-maintenance and protection from contaminants. |
|
| |
| |
|
|
|
| |
| |
| Model |
MX 57EX |
| AC AMPERES |
|
| Range |
500μA |
5mA |
50mA |
500mA |
|
| Resolution |
10nA |
100nA |
1µA |
10µA |
|
| Bandwidth |
DC to 5kHz |
|
| Accuracy |
0.75% of rdg. ± 30cts |
0.6% of rdg. ± 30cts |
0.6% of rdg. ± 30cts |
0.7% of rdg. ± 30cts |
|
| Overload Protection |
600Vrms |
|
| AC VOLTS |
|
| Range |
500mV |
5V |
50V |
500V |
750V |
|
| Resolution |
10μV |
100µV |
1mV |
10mV |
100mV |
|
| Bandwidth |
40Hz to 1kHz |
1kHz to 4kHz |
4kHz to 10kHz |
10kHz to 30kHz |
30kHz to 50kHz |
|
| Accuracy |
±0.3% of rdg. ± 30cts |
±0.3% of rdg. ± 30cts |
±0.3% of rdg. ± 30cts |
±0.3% of rdg. ± 30cts |
±0.3% of rdg. ± 30cts |
|
| Impedance |
11MΩ |
11MΩ |
10MΩ |
10MΩ |
10MΩ |
|
| Overload Protection |
1100Vpk |
| DC AMPERES |
|
| Range |
500µA |
5mA |
50mA |
500mA |
|
| Resolution |
10nA |
100nA |
1µA |
10µA |
|
| Accuracy |
±0.2% of rdg.± 5cts |
±0.2% of rdg.± 2cts |
±0.05% of rdg.± 2cts |
±0.2% of rdg.±2cts |
|
| Overload Protection |
600Vrms |
|
| DC VOLTAGE |
|
| Range |
500mV |
5V |
50V |
500V |
1000V |
|
| Resolution |
10μV |
100µV |
1mV |
10mV |
100mV |
|
| Accuracy |
±0.07% of rdg.± 5cts |
±0.07% of rdg.± 2cts |
±0.07% of rdg.± 2cts |
±0.3% of rdg.± 2cts |
±1% ofrdg.± 2cts |
|
| Impedance |
11MΩ |
11MΩ |
10MΩ |
10MΩ |
10MΩ |
|
| Overload Protection |
1100Vpk |
|
| RESISTANCE |
|
| Range |
500Ω |
5kΩ |
50kΩ |
500kΩ |
5MΩ |
50MΩ |
| Resolution |
10mΩ |
100mΩ |
1Ω |
10Ω |
100Ω |
1kΩ |
| Accuracy |
±0.07% of rdg. ± 5cts |
±0.07% of rdg.± 2cts |
±0.07% of rdg.± 2cts |
±0.07% of rdg.± 2cts |
±0.07% of rdg.± 2cts |
±0.07% of rdg.± 2cts |
| Max. Open-Circuit |
7V |
| Overload Protection |
600Vrms |
| CONTINUITY |
|
| Range |
10Ω to 20Ω |
| Response Time |
1ms |
| DIODE |
|
| Test Voltage |
0 to 2V |
| Test Current |
1mA ± 20% |
| CAPACITANCE |
|
| Range |
50nF to 50mF |
| Accuracy |
1% of Reading ± 2cts |
| FREQUENCY |
|
| Range |
0.62Hz to 500kHz |
| Accuracy |
0.03% of Reading ± 2cts |
| TEMPERATURE |
|
| Range (°C - °F) |
-328° to 1472°F (-200° to 800°C) |
| Sensor |
PT100/PT1000 |
|
|
| |
| General Specifications |
| Digital Display |
50,000-count |
| Analog Bargraph |
34-segment |
| Power Source |
9V Alkaline battery |
| Dimensions |
7.4 x 3.2 x 1.5" (189 x 82 x 40mm) |
| Weight |
0.8 lb (400g) |
| ENVIRONMENTAL |
|
| Operating Temp. |
14° to 104°F (-10° to 40°C) |
| Storage Temp. |
-40° to 158°F (-40° to 70°C) |
| SAFETY |
|
| Safety Rating |
EN 50014, EN50020 |
| Agency Approval |
II 2 G/D EEx ib IICT6 or I M2 EEx ib I assigned specs. |
| EMC |
Emission and immunity as per NF EN 61326-1, 1998 |
| CE Mark |
Yes |
|
| |
| |
|
|
|
| |
| |
Specifications |
|
|
|
 |
| |
 |
| |
Related urls: |
|
|
| |
- Model MX57EX, [ 2130.65] (TRMS, 50,000-count, 0.025% Accuracy)
- Model MX56 III, [ 2116.72] (TRMS, 50,000-count, 0.025% Accuracy)
- Model MX55 III, [ 2116.71] (TRMS, 50,000-count, 0.025% Accuracy)
- Model MX54 III, [ 2116.70] (TRMS, 50,000-count, 0.025% Accuracy)
- Model MX53 III, [ 2116.69] (TRMS, 50,000-count, 0.025% Accuracy)
- Model CA5240, [ 2116.77] (40,000-count, TRMS, 0.1% Accuracy)
- Model MX26, [ 2116.25] (5000-count, TRMS, 0.3% accuracy)
- Model MX24B, [ 2116.24] (5000-count, TRMS, 0.3% accuracy)
- Model MX23, [ 2116.23] (5000-count, TRMS, 0.3% accuracy)
- Model CA5260, [ 2116.77] (4000-count, Average Sensing, 1% Accuracy)
- Model CA5230, [ 2116.76] (4000-count, Average Sensing, 1% Accuracy)
- Model CA5220, [ 2116.75] (4000-count, Average Sensing, 1% Accuracy)
- Model CA5210, [ 2116.74] (4000-count, Average Sensing, 1% Accuracy)
- Model MX22, [ 2119.22] (4000-count, Average Sensing, 1% Accuracy)
- Model MX21, [ 2119.21] (2000-count, Average Sensing, 1% Accuracy)
- Model CA5205, [ 2116.73] (2000-count, Average Sensing, 1% Accuracy)
|
|
| |
|
| |
|
|
|