The AEMC® MR Series AC/DC Probes
are professional AC/DC current
probes designed to extend current
measuring capabilities of DMMs,
oscilloscopes and other instruments.
They are built to the latest safety and
performance standards, including the
CE Mark and UL approval. Two
different hook-shaped jaws are
offered, both permitting the user to
“pry” or “hook” onto cables (will
accept 2 x 500MCM) or even onto
small bus bars.
The MR Series probes use Hall effect
technology and measure AC and DC
current. The electronics and batteries
are self-contained in the handles. The
output of the AC/DC probes is 1mV/A
and 10mV/A. The Model MR411
measures to 400AAc/600ADC. The
Model MR410 has two ranges and an
auto-zero push button (patent
pending) for quick DC zeroing.
There is no output filtering — True
RMS with DC component measurements
are possible. Phase shift is
excellent, making the MR Series of
current probes well suited for power
and power quality applications. |
.jpg) |
|
|
|
| |
|
| |
![Model MR410 [Cat. No. 1200.70] AC/DC Current (1mV/A - 600A max)](/Assets/jpgs/AEMC/Current_Probes/BNC_Probes/1200.72.jpg) |
- Measurement range:
400AAC/600ADC
- Distinct jaw shapes to be used for
hooking or prying around the
conductor
- Auto-zero push button
- Conforms to EN 61010, 600V,
Cat. III safety standard
- Low phase shift for power
measurements
- mV output signals
- Designed for DMMs, recorders,
oscilloscopes, power and
harmonic meters
- Double Insulation
|
|
|
|
| |
|
|
|
| |
| |
- DC motors
- Batteries
- Automobile engine testing
- Power measuring quality analysis
- Power load monitoring
|
|
| |
| |
|
|
|
| |
 |
The MR410 is a general purpose 400AAC or 600ADC current probe designed for use with DMMs, loggers or oscilloscopes and other instruments that have voltage inputs. The MR410 is a single range probe. The MR410 has an integral 5 ft (1.5m) lead terminated by shrouded banana plugs. |
|
| |
| |
|
|
|
| |
| |
| MR410 |
|
| ELECTRICAL |
|
| Nominal Range |
400AAC/600ADC |
| Measurement Range |
0.2 to 600A |
| Output Signal(s) |
60A: 10mV/A
600A: 1mV/A |
Accuracy
(400A Range) |
1 to 100A |
1.5% of Reading ± 1A |
| 100 to 400AAc |
2% of Reading |
| Phase Shift (400AAC Range) |
10 to 200A |
≤2.5° |
| 200 to 400AAC |
≤2.0° |
Accuracy
(600ADC Range) |
10 to 100A |
2.5% of Reading |
| 100 to 600A |
| 2.5% of Reading |
| Phase Shift (600ADC Range) |
10 to 100A |
--- |
| 100 to 400A |
--- |
| Overload |
1kAAC and 2kADC continuous to 1kHz |
| Frequency Range |
DC to 10kHz @ -3dB |
| Load Impedance |
>100kΩ/100pF max |
| Working/Common Mode Voltage |
600Vrms |
| Battery |
9V Alkaline (Approx. 50 hours life) |
| Output Termination |
5 ft Lead |
| MECHANICAL |
| Operating Temperature |
14° to 131°F (-10° to 55°C) |
| Storage Temperature |
-40° to 176°F (-40° to 70°C) |
| Operating Relative Humidity |
10 to 35°C 90% ± 5% RH (without condensation), 40 to 55°C 70% ± 5% RH (without condensation) |
| Zero Adjustment |
Auto-zero |
| Jaw Opening |
1.2" (31mm) |
| Maximum Conductor Size |
One 1.18" (30mm) or two 0.95" (24mm) or two bus bar1.2 x 0.4" (31.5 x 10mm) |
| Dimensions |
8.8 x 3.82 x 1.73" (224 x 97 x 44mm) |
| Weight |
15 oz (440g) |
| Polycarbonate Material |
Handles: Polycarbonate +ABS, Gray, UL94 V0. Jaws: Polycarbonate, Red, UL94 V0 |
| SAFETY |
| Electrical |
EN 61010-2-32 |
| Double Insulation |
Yes |
| CE Mark |
Yes |
|
|
| |
| |
|
|
|
| |
| |
Specifications |
|
|
|
 |
| |
 |
|
|
.jpg) |
|