The AmpFlex® is a flexible AC current
probe composed of a flexible sensor
and an electronic module. The flexible
sensor permits measurements on
conductors where standard clamp-on
probes cannot be used. In particular, it
can be installed in tight spaces, around
cable bundles, around wide or large bus
bars, or even wrapped around irregular
shapes.
The Shape Memory feature
enables the user to pre-shape the sensor
before inserting it between or around
conductors. This feature facilitates
positioning the sensor around the
conductor, enhances user safety, and
alleviates the drooping effect associated
with other flexible sensors.
The AmpFlex® is lightweight and does
not use magnetic cores like standard
transformers. The transformation
principle is based on an air core. It
presents virtually no load to the system
under test, has a low phase shift and
excellent frequency response, and
cannot be damaged by current overloads.
The sensor assembly is waterproof
and insulated for 1000V working
voltage.
The AmpFlex® meets EN 61010
and is CE marked.
The AmpFlex® has a mV output
proportional to the current measured for
direct readings on DMMs, loggers,
oscilloscopes and power or harmonic
meters. The length of the flexible sensor
can be selected from 24" (450mm) to 60"
(1520mm). Longer lengths are available |
.jpg) |
|
|
|
| |
|
| |
|
|
| |
|
|
|
|
| |
| |
- Accuracy 1% of Reading
- TRMS measurements when connected to a TRMS instrument
- No core saturation or damage if overloaded
- Waterproof sensor
- Shape Memory for custom pre-shaping of sensor before use
- Very high frequency response
- Low phase shift for power measurements
- Insensitive to DC, measures only AC component on DC + AC signals
- Excellent linearity
- Lightweight
|
|
| |
| |
|
|
|
| |
| |
- Measuring wide bus bars
- Measuring crowded circuit breaker panels
- Measuring around large cable bundles
- Measuring in any traditional application
- Measuring around irregular shapes
|
|
| |
| |
|
|
|
| |
 |
The AmpFlex® is a flexible AC current probe composed of a flexible sensor and an electronic module. The flexible sensor permits measurements on conductors where standard clamp-on probes cannot be used. Measurement range is 5 to 200A. Output signal is 1mV/A. Sensor length is 24".
|
|
| |
| |
|
|
|
| |
| |
| 200-24-1-1 |
|
| ELECTRICAL |
|
| Current Range |
200A |
| Measurement Range |
5 to 200A |
| Output Signal(s) |
1mV/A |
| Crest Factor
(mid-range) |
>10 |
| Phase Shift @ 50/60Hz |
0.7° |
| Residual Noise |
200mA |
| GENERAL |
| Accuracy |
1% of Reading |
| Frequency Range |
10 to 20,000Hz* |
| Working Voltage |
EN 61010, 1000V Cat.III |
| Safety Standards |
EN 61010, CE Mark and UL listed (E143005) |
| Operating Temperature and %RH |
14° to 131°F (-10° to 55°C) (sensor to 90°C),
10 to 90% RH (@50°C) |
| Minimum Bend Radius |
0.75" (19mm) |
| Water and Dustproofing |
Sensor IP45, Module IP40 |
| Battery and Battery Life |
9V Alkaline, approx. 150 hours of continuous use |
| Good Battery Indication |
Green LED |
| Electronic Overload Indication |
Red LED |
| Output |
3/4 spaced banana jacks,
optional banana plug to BNC adaptor available,
6.5 ft (2m) lead from sensor to module |
|
|
| |
| |
|
|
|
| |
| |
Specifications |
|
|
|
 |
| |
 |
|
|