The Model K110 has exceptional AC/DC
current measurement capabilities. Very
small and compact, this microprobe is
designed for accurate measurement
of very low currents with 50μADC
sensitivity.
Its very small size and “clip” shape
make it ideal for probing and measuring
in tight wiring areas such as circuit
boards, 4 to 20mA process loops or
automotive electronic circuitry. Model
K110 is an excellent companion to all
DMMs and instruments that will benefit
from the probe’s high sensitivity,
dynamic range and waveform displaying
characteristics.
The Model K110 provides higher
sensitivity and better accuracy with
an output of 10mV/mA. It provides
AC + DC output signal proportional to
the total current under test, without
the need of probe ranging or signal
filtering. True RMS measurements
with total AC + DC components are
possible. |
.jpg) |
|
|
|
| |
|
| |
|
|
| |
|
|
|
|
| |
| |
- Measures extremely low level DC from 100µA
- Outputs signal proportional to total current (DC + AC)
- Low noise
- Ultra-compact size and non-contact clamp-on convenience
- Simple plug-in operation
- Designed for use with DMMs and oscilloscopes
- Accurate display of waveforms
- No range or mode (AC/DC) switching required
- Extended battery life
- Red LED indicated momentary or continuous overload
- Green LED indicates power and battery condition
|
|
| |
| |
|
|
|
| |
| |
- ndustrial process controls (4 to 20mA current loops)
- Electronic circuit design, testing and repair
- Automobile wiring and engine control systems
- Avionics systems maintenance and repair
- Shipboard maintenance and repair
- Fault and signal location in complex networks
- Ground and leakage current measurement
- Pre-deployment testing of power-conscious equipment
|
|
| |
| |
|
|
|
| |
 |
he DC/AC Microprobe Model K110 measures as low as 100µA AC or DC. The unit has proportional mV output for direct readings on DMMs. The high accuracy K110 is ideal for calibration of current loop process instruments (e.g., 4 to 20mA or 0 to 20mA). |
|
| |
| |
|
|
|
| |
| |
| K100 |
|
| ELECTRICAL |
|
| Current Range |
0 to 300mArms/0 to ±450mADC |
| Measurement Range |
0 to ±450mA |
| Output Signal(s) |
10mV/mA |
Accuracy
(450mA Range) |
AC |
±0.8% of Reading ± 200μA |
| DC |
±0.5% of Reading ± 150μA |
| Overload |
Red LED indicates momentary or continuous overload |
| Frequency Range |
DC to 1.5kHz (@ -3dB sine) |
| Impedance |
200Ω |
| Working Voltage |
300V, EN 61010-1, Cat. II |
| Battery |
9V Alkaline, NEDA 1604, 6LR61 or IEC 6 LF22
(Approx. 20 hours life) |
| Output Termination |
4mm Safety Banana Jacks |
| MECHANICAL |
|
| Operating Temperature |
-14° to 131°F (-10° to 55°C) |
| Storage Temperature |
-40° to 176°F (-40° to 80°C) |
Operating Relative
Humidity |
<95% @ ≤ 35°C, 75% @ 55°C |
| Zero Adjustment |
±25mA approx. by 10 turn knob at base of case |
| Maximum Conductor Size |
3/16", 0.180" (4.5mm) |
| Dimensions |
Probe: 4.4 x 0.6 x 1.0" (111 x 15 x 25mm);
Electronic Module: 4.9 x 2.5 x 1.1" (124 x 64 x 28mm) |
| Weight |
9 oz (250g) |
| MECHANICAL |
|
| Electrical |
EN 61010-2-32 |
| Double Insulation |
Yes |
| CE Mark |
Yes |
|
|
| |
| |
|
|
|
| |
| |
Specifications |
|
|
|
 |
| |
 |
|
|
.jpg) |
|
\