.jpg) |
|
|
|
| |
|
| |
 |
- Hand-held size, ultra practical and ergonomic design
- TRMS measurement through fast sampling - accurate on non-linear waveforms
- 4kHz Bandwidth
- 3.5 Crest Factor at 600Arms and 900Vrms
- Peak function captures 500µs signals
- Measure Inrush Current on 0.5, 1, 2.5, 5 and 10 cycles (15 to 70Hz)
- Min/Max automatic capture of extreme values at 100ms samples
- Continuity at programmable buzzer threshold from 1-40Ω
- Selectable V-Live™ function (buzzer) warns of live circuit
- Automatic DC current zeroing
- Backlit LCD
- Battery life displayed directly in hours
- EN 61010-1, EN 61010-2-032, 600V Cat. III
- Includes soft carrying case and test leads
|
|
|
|
| |
| |
|
|
|
|
| |
| |
- Electrical maintenance
- Electrical power distribution
- Safety lighting system maintenance
- Automotive test troubleshooting
- Industrial maintenance
- HVAC
|
|
| |
| |
|
|
|
| |
 |
The Model F07, Clamp-on Meter, is a high performance Clamp-on meter built into a rugged compact sized case, with exceptional ergonomic design and extraordinary measurement possibilities.
Integrating a fast microprocessor sampling at a high rate, the Model F07 is completely automatic and performs TRMS measurements on the most distorted waveforms. The Model F07 measures TRMS Voltage and Current and can incorporate the DC component of the signal for the Truest RMS. It has a V-Live™ function to warn of the use of live circuits or elevated voltages.Temperature measurements up to 1832°F (1000°C) can be taken via standard K thermocouple. The Model F07 can measure in-rush currents from 1 cycle up to 10 cycles and frequency. Other features include: auto-ranging, 4000-count display and Auto-Off.
|
|
| |
| |
|
|
|
| |
| |
| True RMS |
Model F07 |
| AC AMPERES |
|
| Measurement Range |
40A
400A
1000A |
0.20 to 39.99A
40.0 to 399.9A
400 to 600A pk |
| Accuracy |
40A
400A
1000A |
1.5% of Reading + 10cts
1.5% of Reading + 2cts
1.5% of Reading + 2cts |
| Resolution |
40A
400A
1000A |
10mA
100mA
1A |
| VOLTAGE |
|
| Measurement Range |
40V
400V
4000V |
0.2 to 39.99V
40.0 to 399.9V
400 to 600V |
| Accuracy |
40V
400V
4000V |
1% of Reading + 5cts
1% of Reading + 2cts
1% of Reading + 2cts |
| RESISTANCE-OHMS |
(Ω) |
| Measurement Range |
400Ω
4000Ω
40kΩ |
0.0 to 399.9Ω
400 to 3999Ω
4.00 to 39.99kΩ |
| Accuracy |
1% of Reading + 2cts |
| DIODE |
|
| Measurement Range 4V |
0 to 3.199V |
| CONTINUITY |
|
| Measurement Range |
0.0 to 399.9Ω |
| Accuracy |
1% of Reading + 2cts |
| INRUSH FUNCTION |
|
| Range for Use |
≥5A pk for the first period of the signal |
| Accuracy |
5% + 0.5A |
|
Capture Time |
0.5 to 10 periods of the signal frequency
(8 to 160ms at 60Hz) |
| FREQUENCY |
(Hz) |
| Measurement Range |
40Hz
400Hz
4000Hz
40kHz |
10.00 to 39.99Hz
40.0 to 399.9Hz
400 to 3999Hz
4.00 to 19.99kHz |
| Accuracy 40Hz to 40kHz |
0.4% of Reading +1ct |
|
|
| |
| General Specifications |
| Digital Display |
4 digits, 9999 counts, 3 decimal points, “+” and “–” signs (DC and peak measurement) |
| Power Source |
9V Alkaline battery
(type IEC 6LF22, 6LR61 or NEDA 1604) |
| Jaw Opening Size Ø |
≤1.00" (≤26mm) |
| Dimension |
2.76 x 7.6 x 1.46" (70 x 193 x 37mm) |
| Weight |
9.17 oz (260g) |
| ENVIRONMENTAL |
|
| Operating Temp. |
32° to 122°F (0° to 50°C); 90% RH |
| Storage Temp. |
-40° to 158°F (-40° to 70°C); 90% RH |
| SAFETY |
|
| Safety Rating |
EN 62020-1, EN 61010-2-032, 600V Cat. III |
| CE Mark |
Yes |
|
| |
| |
|
|
|
| |
| |
Specifications |
|
|
|
 |
| |
 |
| |
Related urls: |
|
|
| |
- Model 500 , (AC, 400AAC, 600VAC, Ohms, Continuity)
- Model 501 , (AC, 400AAC, 600VAC/DC, Ohms, Continuity)
- Model 502 , (TRMS, 400AAC, 600VAC/DC, Ohms, Continuity)
- Model 503 , (AC/DC, 400AAC/DC, 600VAC/DC, Ohms, Continutiy)
- Model 511 , (AC, 1000AAC, 1000VAC/DC, Ohms, Continuity)
- Model 512 , (TRMS, 1000AAC, 600VAC/DC, Ohms, Continuity)
- Model 514 , (AC/DC, TRMS, 1000AAC/DC, 600VAC/DC, Ohms,
Continuity)
- Model F1N ,(AC, TRMS, 400A, Hz)
- Model F3N , (AC, TRMS, 400A, Hz, Peak, Smooth, Min/Max)
- Model F01 , (TRMS, 400AAC, Ohms, Continuity)
- Model F03 , (TRMS, 400AAC/DC, 600VAC/DC, Ohms, Continuity, Temp.)
- Model F05 , (TRMS, 400AAC/DC, 600VAC/DC, Hz, Power (kW), Phase Rotation, Ohms, Continuity)
- Model F07, (TRMS, 400AAC/DC, 600VAC/DC, Hz, Ohms, Continuity, Temperature)
- Model F25 , (TRMS, 600VAC/DC & 1500AAC/DC)
- Model 721 , (9999-count, TRMS, V, A, F, Hz, THD, CF)
|
|
| |
|
| |
|
|
|
.jpg) |
|