.jpg) |
|
|
|
| |
|
| |
 |
- Hand-held size, ultra practical and ergonomic design
- TRMS measurement through fast sampling - accurate on non-linear waveforms
- 4kHz Bandwidth
- 3.5 Crest factor at 600Arms and 900Vrms
- Peak function captures 500µs signals
- Min/Max automatic capture of extreme values at 100ms samples
- Continuity at programmable threshold from 1 to 40Ω
- Selectable V-Live™ function (buzzer) warns of live circuit
- Battery life displayed directly in hours at the push of a button
- Automatically detects AC or DC Volts and Amperes and (auto-ranging)
- Backlit LCD
- EN 61010-1, EN 61010-2-032, 600V Cat. III
- Includes soft carrying case and test leads
|
|
|
|
| |
| |
|
|
|
|
| |
| |
- Electrical maintenance
- Electrical power distribution
- Safety lighting system maintenance
- Automotive test troubleshooting
- Industrial maintenance
- HVAC
|
|
| |
| |
|
|
|
| |
 |
The Model F03, Clamp-on Meter, is a high performance Clamp-on meter built into a rugged compact sized case, with exceptional ergonomic design and extraordinary measurement possibilities.
Integrating a fast microprocessor sampling at a high rate, the Model F03 is completely automatic and performs TRMS measurements on the most distorted waveforms. The Model F03 automatically detects AC or DC in Voltage and Current. It has a V-Live™ function to warn user of live circuits and elevated voltages.Temperature measurements up to 1832°F (1000°C) can be taken via standard K thermocouple. Other features include: auto-ranging, 4000-count display and Auto-Off. |
|
| |
| |
|
|
|
| |
| |
| True RMS |
Model F03 |
| AC AMPERES |
|
| Measurement Range |
40A
400A
1000A |
0.20 to 39.99A
40.0 to 399.9A
400 to 600A pk |
| Accuracy |
40A
400A
1000A |
1.5% of Reading + 10cts
1.5% of Reading + 2cts
1.5% of Reading + 2cts |
| Resolution |
40A
400A
1000A |
10mA
100mA
1A |
| VOLTAGE |
|
| Measurement Range |
40V
400V
4000V |
0.2 to 39.99V
40.0 to 399.9V
400 to 600V |
| Accuracy |
40V
400V
4000V |
1% of Reading + 5cts
1% of Reading + 2cts
1% of Reading + 2cts |
| RESISTANCE-OHMS |
(Ω) |
| Measurement Range |
400Ω
4000Ω
40kΩ |
0.0 to 399.9Ω
400 to 3999Ω
-- |
| Accuracy |
1% of Reading + 2cts |
| DIODE |
|
| Measurement Range 4V |
0 to 3.199V |
| CONTINUITY |
|
| Measurement Range |
0.0 to 399.9Ω |
| Accuracy |
1% of Reading + 2cts |
|
|
| |
| General Specifications |
| Digital Display |
4 digits, 9999 counts, 3 decimal points, “+” and “–” signs (DC and peak measurement) |
| Power Source |
9V Alkaline battery
(type IEC 6LF22, 6LR61 or NEDA 1604) |
| Jaw Opening Size Ø |
≤1.00" (≤26mm) |
| Dimension |
2.76 x 7.6 x 1.46" (70 x 193 x 37mm) |
| Weight |
9.17 oz (260g) |
| ENVIRONMENTAL |
|
| Operating Temp. |
32° to 122°F (0° to 50°C); 90% RH |
| Storage Temp. |
-40° to 158°F (-40° to 70°C); 90% RH |
| SAFETY |
|
| Safety Rating |
EN 62020-1, EN 61010-2-032, 600V Cat. III |
| CE Mark |
Yes |
|
| |
| |
|
|
|
| |
| |
Specifications |
|
|
|
 |
| |
 |
| |
Related urls: |
|
|
| |
- Model 500 , (AC, 400AAC, 600VAC, Ohms, Continuity)
- Model 501 , (AC, 400AAC, 600VAC/DC, Ohms, Continuity)
- Model 502 , (TRMS, 400AAC, 600VAC/DC, Ohms, Continuity)
- Model 503 , (AC/DC, 400AAC/DC, 600VAC/DC, Ohms, Continutiy)
- Model 511 , (AC, 1000AAC, 1000VAC/DC, Ohms, Continuity)
- Model 512 , (TRMS, 1000AAC, 600VAC/DC, Ohms, Continuity)
- Model 514 , (AC/DC, TRMS, 1000AAC/DC, 600VAC/DC, Ohms,
Continuity)
- Model F1N ,(AC, TRMS, 400A, Hz)
- Model F3N , (AC, TRMS, 400A, Hz, Peak, Smooth, Min/Max)
- Model F01 , (TRMS, 400AAC, Ohms, Continuity)
- Model F03 , (TRMS, 400AAC/DC, 600VAC/DC, Ohms, Continuity, Temp.)
- Model F05 , (TRMS, 400AAC/DC, 600VAC/DC, Hz, Power (kW), Phase Rotation, Ohms, Continuity)
- Model F07, (TRMS, 400AAC/DC, 600VAC/DC, Hz, Ohms, Continuity, Temperature)
- Model F25 , (TRMS, 600VAC/DC & 1500AAC/DC)
- Model 721 , (9999-count, TRMS, V, A, F, Hz, THD, CF)
|
|
| |
|
| |
|
|
|
.jpg) |
|