Spacer Home Contact_us ob Opportunities ISO_Registration Privacy_Statement
 
header

AEMC®Instruments

Model 721 [Catalog No. 1208.52]
Clamp-on Meters

 
previous URL Next URL
< Links >
 
 
 
AEMC® Model 721 Clamp-On Meters

Characteristics:

  • Designed for traditional and nonlinear loads
  • Simple Clamp-on operation with power quality features
  • No menus, no calculations and no analyzing
  • Accurate True RMS readings of amperes and volts
  • Direct reading of %THD, %DF, CF and Peak
  • Recording mode for Min, Max, Avg, Max Peak
  • Works with oscilloscopes as a harmonic and current transducer
  • Rugged Lexan construction for professional daily use
  • Compact size
  • Designed to EN 61010, 600V Cat. III safety standards
 
 
  Application:  
 
 
  • True RMS voltage and current values on any circuit
  • Identify harmonic distortion patterns and sources of voltage harmonics
  • Identify dominant load types in circuits
  • Identify linear and nonlinear loads
  • Locate sources of harmonic current
  • Derating transformers
  • Track down overloaded or unbalanced circuits
  • Reduce system overloads
  • Measure output frequency of adjustable speed drive controllers
 
 
  Product Description:  
 
space

The Model 721 combines the simplicity and familiarity of digital Clamp-ons with today's critical information on power quality and harmonics.

Operation is simple and direct, with no menus, calculations or complex analyzer procedures. Select Amps or Volts on the rotary dial, connect, and measure. The push of a button gives additional information. You can troubleshoot and measure power quality with the ease of using a digital Clamp-on - simply, safely, and economically.

 
 
  Specifications:  
 
 
True RMS

Model 721

AC AMPERES  
Measurement Range 0.05 to 700.0Arms
0.05 to ±999.9A peak
Accuracy 0.3 to 99.99A: 2% of Reading ± 20cts
100.0 to 400.0A: 2% of Reading
400.0 to 700.0A: 5% of Reading
Crest Factor >3.0 below 300A
Frequency Range 15Hz to 10kHz
AC VOLTAGE  
Measurement Range 0.05 to 600Vrms
0.05 to ±1200V peak
Accuracy 0.5 to 400.0V: 1.5% of Reading ± 4cts
400.0 to 999.9V: 1.5% of Reading
Crest Factor >4.0 below 300V
Input Impedance 1MΩ, 47pF
Frequency Range 15Hz to 10kHz
TOTAL HARMONIC DISTORTION (%THD)
Range 0.5% to 600.0%, 25th order
Resolution 0.1%
Minimum Input 300mA, 300mV
Accuracy 0 to 100%: 10% of Reading ± 5cts; 100 to 200%: 15% of Reading
Frequency Range Fundamental 45 to 65Hz, 25th harmonic
Display Digital: %THD and True RMS (A or V)
DISTORTION FACTOR (%DF)
Range 0.5% to 100%
Resolution 0.1%
Minimum Input 300mA, 300mV
Basic Accuracy 0 to 100%: 10% of Reading ± 5cts
Frequency Range Fundamental 45 to 65Hz, 25th harmonic
Display Digital: %DF; Bargraph: True RMS (A or V)
CREST FACTOR (CF)
Range 1.00 to 10.00
Resolution 0.01
Minimum Input 300mA, 300mV
Basic Accuracy ±10% of Reading ± 3cts (40 to 450Hz)
Frequency Range 15Hz to 10kHz
Display Digital: CF; Bargraph: True RMS (A or V)
FREQUENCY (HZ)
Range 0.5 to 9999Hz
Minimum Input 1A or 1V
Accuracy 0.5Hz to 999.9Hz: 0.1% of Reading ± 1ct; 1000Hz to 9999Hz: 0.2% of Reading ± 1ct
Display Digital: Hz measurement; Bargraph: True RMS (A or V)
ANALOG OUTPUT
Range 1mV/A (0.05 to 700 Arms), or 10mV/A (0.05 to 60 Arms)
Basic Accuracy 3%
Input 0.05A to 999.9A peak
Output Impedance 4Ω, 47pF
Display Digital: all A and THD functions; Bargraph: Arms
 
 
  Downloads:  
 
  pdf_pic Downloads: Specifications  
base
 
 
Scroll down
 
scroll
 
  scroll up  
 
index mail web