Spacer Home Contact_us ob Opportunities ISO_Registration Privacy_Statement
 
header

AEMC®Instruments

Model 511 [Catalog No. 2117.67]
Clamp-on Meters

 
previous URL Next URL
< Links >
 
 
 
AEMC® Model 511 Clamp-On Meters

Characteristics:

  • Standard size, full function Clamp-on meter
  • 1000AAC current measurements
  • 750VAC/1000VDC volt measurements
  • Resistance measurement to 4000Ω
  • Continuity with beeper below 40Ω
  • Frequency measurements from V and A
  • Diode test
  • 1ms Peak function for fast capture of signals
  • Hold function to "freeze" readings
  • Push-button for easy ADC zeroing
  • Large easy-to-read 4000-count display
  • 42-segment analog bargraph
  • Includes test leads and soft carrying pouch
 
 
  Application:  
 
 
  • Commercial, industrial, residential and HVAC troubleshooting
  • Power panel, junction box and battery bank monitoring
  • AC or DC motor testing
  • Power plant troubleshooting
  • Electrical testing and troubleshooting on traditional loads
 
 
  Product Description:  
 
space

The Model 511, Clamp-on Meter, is a general purpose professional Clamp-on meter that measures up to the toughest standards. It is built into a rugged mechanical case and is designed using quality polycarbonate materials. This meter offers a complete set of measurement ranges and is in compliance with international safety and quality standards to ensure a professional and reliable measuring tool.

The Model 511 is auto-ranging and provides the best measurement range and resolution for troubleshooting. It has a high resolution 40A range. The Model 511 measures AC Amps, AC Volts, DC Volts, Ohms, Continuity (with beeper), Frequency (from V or A) and has a Diode Test function.

The Model 511 is sized for a comfortable, one-handed operation. This model is average sensing and designed for traditional average responding electrical systems. The jaw opening for the Model 511 is 1.575" (40mm).
 
 
  Specifications:  
 
 
Average Sensing Model 511
AC AMPERES  
Measurement Range 0.05A to 1000A
Resolution 40A
400A
1000A
0.01A
0.1A
1A
Accuracy 50 to 60Hz
60 to 500Hz
±1.9% of Reading ± 5cts
±1.9% of Reading ± 5cts
Overload Protection 40A
400A
1000A
800Arms
1500Arms
1500Arms
AC VOLTS  
Measurement Range 0.5V to 750V
Resolution 400V
750V
0.1V
1V
Accuracy 50 to 500Hz ±1.2% of Reading ± 5cts
Input Impedance 1MΩ
Overload Protection 1000Vrms
DC VOLTS  
Measurement Range 0.2 to 600V
Resolution 400V
600V
0.1V
1V
Accuracy ±0.75% of Reading ± 2cts
Input Impedance
10MΩ
Overload Protection
1200Vrms
RESISTANCE-OHMS (Ω)
Measurement Range 0.2 to 4000Ω
Resolution 400Ω
4000Ω
0.1Ω
Accuracy ±1% of Reading ± 2cts
Max Test Voltage
3 VDC
Overload Protection
600Vrms
DIODE  
Test Current 0.6mA
Overload Protection 600Vrms
Open Circuit Voltage 3 VDC
CONTINUITY  
Beeper Activation <40Ω
Max. Test Voltage 3 VDC
Overload Protection 600Vrms
FREQUENCY (Hz)  
CURRENT INPUT  
Range  
4kHz
10kHz
1Hz Resolution
--
Accuracy (20Hz to 10kHz) ±0.1% of Reading ± 1ct
Min Input Signal  
4kHz
10kH
2Arms
--
VOLTAGE INPUT  
Range  
4kHz
40kHz
1Hz Resolution
10Hz Resolution
Accuracy (20Hz to 10kHz)
±0.1% of Reading ± 1ct
Min Input Signal  
4kHz
40kHz
5Vrms
5Vrms
 
 
General Specifications
Digital Display 3 3/4 digits LCD display, 4000-count (max. reading 3999)
Analog Display Fast 42-segment analog bargraph display
Symbol & Scale Range Automatic according to range and input signal
Polarity Displayed when negative signal applied to input
Overload Displayed when input signal exceeds range
Sample Rate 2 samples/sec for the digital display, 20 samples/sec for the analog bargraph
Power Source 9V, NEDA 1604 or 6F22 or 006P
Auto-Off 30 minutes
Low Power Indication Displayed when the battery is below the required voltage
Jaw Opening Size Ø 1.575" (40mm) – faciliates 750MCM cable or two 500MCM cab
Dimension 9.53 x 2.60 x 1.42" (242 x 66 x 36mm)
Weight 14.10 oz (400g) with batteries
ENVIRONMENTAL  
Altitude 2167 ft (2000m) max.
Operating Temperature 32° to 104°F (0° to 40°C),
<80% RH, non-condensing
Storage Temperature 14° to 140°F (-10° to 60°C),
<70% RH, battery removed
Pollution Degree 2
SAFETY  
Safety Rating EN 61010, 600V Cat. II, EN 61010, 10000V Cat. III
CE Mark Yes
 
  Downloads:  
 
  pdf_pic Downloads: Specifications  
base
 
 
Scroll down
 
scroll
 
  scroll up  
 
index mail web