.jpg) |
|
|
|
| |
|
| |
 |
- Standard size, full function Clamp-on meter
- 1000AAC current measurements
- 750VAC/1000VDC volt measurements
- Resistance measurement to 4000Ω
- Continuity with beeper below 40Ω
- Frequency measurements from V and A
- Diode test
- 1ms Peak function for fast capture of signals
- Hold function to "freeze" readings
- Push-button for easy ADC zeroing
- Large easy-to-read 4000-count display
- 42-segment analog bargraph
- Includes test leads and soft carrying pouch
|
|
|
|
| |
| |
|
|
|
|
| |
| |
- Commercial, industrial, residential and HVAC troubleshooting
- Power panel, junction box and battery bank monitoring
- AC or DC motor testing
- Power plant troubleshooting
- Electrical testing and troubleshooting on traditional loads
|
|
| |
| |
|
|
|
| |
 |
The Model 511, Clamp-on Meter, is a general purpose professional Clamp-on meter that measures up to the toughest standards. It is built into a rugged mechanical case and is designed using quality polycarbonate materials. This meter offers a complete set of measurement ranges and is in compliance with international safety and quality standards to ensure a professional and reliable measuring tool.
The Model 511 is auto-ranging and provides the best measurement range and resolution for troubleshooting. It has a high resolution 40A range.
The Model 511 measures AC Amps, AC Volts, DC Volts, Ohms, Continuity (with beeper), Frequency (from V or A) and has a Diode Test function.
The Model 511 is sized for a comfortable, one-handed operation. This model is average sensing and designed for traditional average responding electrical systems. The jaw opening for the Model 511 is 1.575" (40mm). |
|
| |
| |
|
|
|
| |
| |
| Average Sensing |
Model 511 |
| AC AMPERES |
|
| Measurement Range |
0.05A to 1000A |
| Resolution |
40A
400A
1000A |
0.01A
0.1A
1A |
| Accuracy |
50 to 60Hz
60 to 500Hz |
±1.9% of Reading ± 5cts
±1.9% of Reading ± 5cts |
| Overload Protection |
40A
400A
1000A |
800Arms
1500Arms
1500Arms |
| AC VOLTS |
|
| Measurement Range |
0.5V to 750V |
| Resolution |
400V
750V |
0.1V
1V |
| Accuracy |
50 to 500Hz |
±1.2% of Reading ± 5cts |
| Input Impedance |
1MΩ |
| Overload Protection |
1000Vrms |
| DC VOLTS |
|
| Measurement Range |
0.2 to 600V |
| Resolution |
400V
600V |
0.1V
1V |
| Accuracy |
±0.75% of Reading ± 2cts |
| Input Impedance |
10MΩ |
| Overload Protection |
1200Vrms |
| RESISTANCE-OHMS |
(Ω) |
| Measurement Range |
0.2 to 4000Ω |
| Resolution |
400Ω
4000Ω |
0.1Ω
1Ω |
| Accuracy |
±1% of Reading ± 2cts |
| Max Test Voltage |
3 VDC |
| Overload Protection |
600Vrms |
| DIODE |
|
| Test Current |
0.6mA |
| Overload Protection |
600Vrms |
| Open Circuit Voltage |
3 VDC |
| CONTINUITY |
|
| Beeper Activation |
<40Ω |
| Max. Test Voltage |
3 VDC |
| Overload Protection |
600Vrms |
| FREQUENCY (Hz) |
|
| CURRENT INPUT |
|
| Range |
|
4kHz
10kHz |
1Hz Resolution
-- |
| Accuracy (20Hz to 10kHz) |
±0.1% of Reading ± 1ct |
| Min Input Signal |
|
4kHz
10kH |
2Arms
-- |
| VOLTAGE INPUT |
|
| Range |
|
4kHz
40kHz |
1Hz Resolution
10Hz Resolution
|
| Accuracy (20Hz to 10kHz) |
±0.1% of Reading ± 1ct |
| Min Input Signal |
|
4kHz
40kHz |
5Vrms
5Vrms
|
|
|
| |
| General Specifications |
| Digital Display |
3 3/4 digits LCD display, 4000-count (max. reading 3999) |
| Analog Display |
Fast 42-segment analog bargraph display |
| Symbol & Scale Range |
Automatic according to range and input signal |
| Polarity |
Displayed when negative signal applied to input |
| Overload |
Displayed when input signal exceeds range |
| Sample Rate |
2 samples/sec for the digital display, 20 samples/sec for the analog bargraph |
| Power Source |
9V, NEDA 1604 or 6F22 or 006P |
| Auto-Off |
30 minutes |
| Low Power Indication |
Displayed when the battery is below the required voltage |
| Jaw Opening Size Ø |
1.575" (40mm) – faciliates 750MCM cable or two 500MCM cab |
| Dimension |
9.53 x 2.60 x 1.42" (242 x 66 x 36mm) |
| Weight |
14.10 oz (400g) with batteries |
| ENVIRONMENTAL |
|
| Altitude |
2167 ft (2000m) max. |
| Operating Temperature |
32° to 104°F (0° to 40°C),
<80% RH, non-condensing |
| Storage Temperature |
14° to 140°F (-10° to 60°C),
<70% RH, battery removed |
| Pollution Degree |
2 |
| SAFETY |
|
| Safety Rating |
EN 61010, 600V Cat. II, EN 61010, 10000V Cat. III |
| CE Mark |
Yes |
|
| |
| |
|
|
|
| |
| |
Specifications |
|
|
|
 |
| |
 |
| |
Related urls: |
|
|
| |
- Model 500 , (AC, 400AAC, 600VAC, Ohms, Continuity)
- Model 501 , (AC, 400AAC, 600VAC/DC, Ohms, Continuity)
- Model 502 , (TRMS, 400AAC, 600VAC/DC, Ohms, Continuity)
- Model 503 , (AC/DC, 400AAC/DC, 600VAC/DC, Ohms, Continutiy)
- Model 511 , (AC, 1000AAC, 1000VAC/DC, Ohms, Continuity)
- Model 512 , (TRMS, 1000AAC, 600VAC/DC, Ohms, Continuity)
- Model 514 , (AC/DC, TRMS, 1000AAC/DC, 600VAC/DC, Ohms,
Continuity)
- Model F1N ,(AC, TRMS, 400A, Hz)
- Model F3N , (AC, TRMS, 400A, Hz, Peak, Smooth, Min/Max)
- Model F01 , (TRMS, 400AAC, Ohms, Continuity)
- Model F03 , (TRMS, 400AAC/DC, 600VAC/DC, Ohms, Continuity, Temp.)
- Model F05 , (TRMS, 400AAC/DC, 600VAC/DC, Hz, Power (kW), Phase Rotation, Ohms, Continuity)
- Model F07, (TRMS, 400AAC/DC, 600VAC/DC, Hz, Ohms, Continuity, Temperature)
- Model F25 , (TRMS, 600VAC/DC & 1500AAC/DC)
- Model 721 , (9999-count, TRMS, V, A, F, Hz, THD, CF)
|
|
| |
|
| |
|
|
|
.jpg) |
|